Difference between revisions of "Start Counter"

From GlueXWiki
Jump to: navigation, search
(Reformatted page and added references to the relevant publications.)
(Replaces obsolete images.)
Line 1: Line 1:
 +
[[File:The_GlueX_Start_Counter_mounted_to_the_liquid_H2_target_assembly.png|thumb|upright=1.0| Fig. 1: The GlueX Start Counter mounted to the liquid H2 target assembly<ref name="GlueXSCpaper">E. Pooser ''et al.'', The GlueX Start Counter Detector, Nucl. Instrum. Meth. A '''927''', 330-342 (2019) [https://doi.org/10.1016/j.nima.2019.02.029 doi:10.1016/j.nima.2019.02.029] [[https://arxiv.org/abs/1901.02759 arXiv:1901.02759] [physics.ins-det]]. </ref>.]]
 +
[[File:Start_Counter_readout_electronics_diagram.png|thumb|Fig. 2: Start Counter readout electronics diagram <ref name="GlueXSCpaper" />.]]
 
== Introduction ==
 
== Introduction ==
 
The Start Counter (SC) surrounds the liquid hydrogen target. The primary purpose of the SC is to identify the photon beam buckets associated with the individual events.
 
The Start Counter (SC) surrounds the liquid hydrogen target. The primary purpose of the SC is to identify the photon beam buckets associated with the individual events.
 
+
For an in-depth discussion of the Start Counter design, construction, and calibration see Eric Pooser's dissertation<ref>Pooser, Eric J., "The GlueX Start Counter & Beam Asymmetry <math>\Sigma</math> in Single <math>\pi^{0}</math> Photoproduction" (2016). FIU Electronic Theses and Dissertations. 2450. [https://digitalcommons.fiu.edu/etd/2450 https://digitalcommons.fiu.edu/etd/2450]</ref>.
For an in-depth discussion of the Start Counter design, construction, and calibration see Eric Pooser's dissertation
+
For a more concise presentation see the NIMA article <ref name="GlueXSCpaper"/>.
<ref>Pooser, Eric J., "The GlueX Start Counter & Beam Asymmetry <math>\Sigma</math> in Single <math>\pi^{0}</math> Photoproduction" (2016). FIU Electronic Theses and Dissertations. 2450. [https://digitalcommons.fiu.edu/etd/2450 https://digitalcommons.fiu.edu/etd/2450]</ref>.
+
For a more concise presentation see the NIMA article <ref>E. Pooser ''et al.'', The GlueX Start Counter Detector, Nucl. Instrum. Meth. A '''927''', 330-342 (2019) [https://doi.org/10.1016/j.nima.2019.02.029 doi:10.1016/j.nima.2019.02.029] [[https://arxiv.org/abs/1901.02759 arXiv:1901.02759] [physics.ins-det]]. </ref>.
+
 
How the SC fits into the full GlueX detector is described in a separate paper <ref> S. Adhikari ''et al.'' [GlueX], The GLUEX beamline and detector, Nucl. Instrum. Meth. A '''987''', 164807 (2021) [https://doi.org/10.1016/j.nima.2020.164807 doi:10.1016/j.nima.2020.164807] [[https://arxiv.org/abs/2005.14272 arXiv:2005.14272] [physics.ins-det]].</ref>.
 
How the SC fits into the full GlueX detector is described in a separate paper <ref> S. Adhikari ''et al.'' [GlueX], The GLUEX beamline and detector, Nucl. Instrum. Meth. A '''987''', 164807 (2021) [https://doi.org/10.1016/j.nima.2020.164807 doi:10.1016/j.nima.2020.164807] [[https://arxiv.org/abs/2005.14272 arXiv:2005.14272] [physics.ins-det]].</ref>.
== Resources ==
+
== Resources (some historical or obsolete) ==
 
* For a recent description see the Start Counter Update  [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=992 GlueX-doc-992]
 
* For a recent description see the Start Counter Update  [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=992 GlueX-doc-992]
 
* [[Start Counter Drawings|Drawings]]
 
* [[Start Counter Drawings|Drawings]]
 
* [[Media:Start counter schedule 2012-11-16 baseline.pdf|Start Counter schedule from Nov. 2012 baseline]]
 
* [[Media:Start counter schedule 2012-11-16 baseline.pdf|Start Counter schedule from Nov. 2012 baseline]]
 
* [http://www.jlab.org/Hall-D/detector/start_counter/SC.pdf Fastrack schedule (draft)]
 
* [http://www.jlab.org/Hall-D/detector/start_counter/SC.pdf Fastrack schedule (draft)]
* Nominal start counter electronics system diagram: [[Image: Electronics Start Counter.png|thumb|Start counter electronics chain]]
+
<!-- * Nominal start counter electronics system diagram: [[Image: Electronics Start Counter.png|thumb|Start counter electronics chain]] -->
 
* [[Start Counter Bi-Weekly Meetings|Start Counter Meetings]]
 
* [[Start Counter Bi-Weekly Meetings|Start Counter Meetings]]
 
* [[Start Counter Cheat Sheet]]
 
* [[Start Counter Cheat Sheet]]
Line 23: Line 23:
 
* [[Start Counter Electronics Channel Maps and Cabling]]
 
* [[Start Counter Electronics Channel Maps and Cabling]]
  
[[Image: SC_30_overview.png|600px|Start counter overview]]
+
<!-- [[Image: SC_30_overview.png|600px|Start counter overview]] -->
  
 
==References==
 
==References==
 
<references />
 
<references />

Revision as of 20:58, 8 November 2022

Fig. 1: The GlueX Start Counter mounted to the liquid H2 target assembly[1].
Fig. 2: Start Counter readout electronics diagram [1].

Introduction

The Start Counter (SC) surrounds the liquid hydrogen target. The primary purpose of the SC is to identify the photon beam buckets associated with the individual events. For an in-depth discussion of the Start Counter design, construction, and calibration see Eric Pooser's dissertation[2]. For a more concise presentation see the NIMA article [1]. How the SC fits into the full GlueX detector is described in a separate paper [3].

Resources (some historical or obsolete)


References

  1. 1.0 1.1 1.2 E. Pooser et al., The GlueX Start Counter Detector, Nucl. Instrum. Meth. A 927, 330-342 (2019) doi:10.1016/j.nima.2019.02.029 [arXiv:1901.02759 [physics.ins-det]].
  2. Pooser, Eric J., "The GlueX Start Counter & Beam Asymmetry \Sigma in Single \pi ^{{0}} Photoproduction" (2016). FIU Electronic Theses and Dissertations. 2450. https://digitalcommons.fiu.edu/etd/2450
  3. S. Adhikari et al. [GlueX], The GLUEX beamline and detector, Nucl. Instrum. Meth. A 987, 164807 (2021) doi:10.1016/j.nima.2020.164807 [arXiv:2005.14272 [physics.ins-det]].