Line 10: Line 10:
 
* KLOE algorithm: currently default
 
* KLOE algorithm: currently default
 
* GlueX algorithm: by Matt Shepherd [[media:New_bcal_recon.pdf | "New" BCAL Reconstruction Algorithm]]
 
* GlueX algorithm: by Matt Shepherd [[media:New_bcal_recon.pdf | "New" BCAL Reconstruction Algorithm]]
* GlueX+: Fixed a bug that prevent some hits from being considered, lowered energy threshold to "seed" cluster
+
* GlueX+: Fixed a bug that prevented some DBCALPoint from being considered, lowered energy threshold to seed cluster, minSeed, from 20 MeV to 10 Mev.
  
 
==Single photon event sample==
 
==Single photon event sample==
  
Single photon efficiency (excluding events with tracking hits):
+
===Single photon efficiency===
 +
Exclude all events with tracking hits (include only events where we actually expect to reconstruct a single)
  
Energy resolution:
+
KLOE: 99%
 +
 
 +
GlueX: 98.5%
 +
 
 +
GlueX+: 99.5%
 +
 
 +
===Energy resolution===
 +
These plots use E_raw, not the corrected/calibrated E. They also exclude events with tracking hits.
  
 
GlueX:
 
GlueX:
Line 27: Line 35:
 
[[Image:E res.AFTER4.png]]
 
[[Image:E res.AFTER4.png]]
  
Timing resolution:
+
===Timing resolution===
  
 
==Single pion event sample==
 
==Single pion event sample==
  
 
==b1pi event sample==
 
==b1pi event sample==

Revision as of 16:27, 24 August 2011

Summary

  • BCAL reconstruction seemed to be an obstacle in b1pi events
  • Two reconstruction algorithms in tree: KLOE algorithm=default, "new" algorithm by matt s.
  • Found two issues which lead to poor energy resolution at low E (fixes not checked in yet)
  • "New" algorithm seems to be doing well for single-photon events
  • Further study of b1pi, etc.
  • Further fine-tuning needed, but maybe should wait until BCAL segmentation finalized?

BCAL Reconstruction algorithms

  • KLOE algorithm: currently default
  • GlueX algorithm: by Matt Shepherd "New" BCAL Reconstruction Algorithm
  • GlueX+: Fixed a bug that prevented some DBCALPoint from being considered, lowered energy threshold to seed cluster, minSeed, from 20 MeV to 10 Mev.

Single photon event sample

Single photon efficiency

Exclude all events with tracking hits (include only events where we actually expect to reconstruct a single)

KLOE: 99%

GlueX: 98.5%

GlueX+: 99.5%

Energy resolution

These plots use E_raw, not the corrected/calibrated E. They also exclude events with tracking hits.

GlueX:

E res.AFTER0.png


GlueX+:

E res.AFTER4.png

Timing resolution

Single pion event sample

b1pi event sample