Difference between revisions of "BCAL reconstruction 8/24/11"

From GlueXWiki
Jump to: navigation, search
Line 17: Line 17:
  
 
Energy resolution:
 
Energy resolution:
 +
GlueX:
 +
[[Image:E res.AFTER0.png]]
 +
 +
GlueX+:
 +
[[Image:E res.AFTER4.png]]
  
 
Timing resolution:
 
Timing resolution:

Revision as of 14:00, 24 August 2011

Summary

  • BCAL reconstruction seemed to be an obstacle in b1pi events
  • Two reconstruction algorithms in tree: KLOE algorithm=default, "new" algorithm by matt s.
  • Found two issues which lead to poor energy resolution at low E (fixes not checked in yet)
  • "New" algorithm seems to be doing well, at least for single-photon events
  • Further fine-tuning needed, but maybe should wait until BCAL segmentation finalized?
  • Further study of b1pi, etc.

BCAL Reconstruction algorithms

  • KLOE algorithm: currently default
  • GlueX algorithm: by Matt Shepherd "New" BCAL Reconstruction Algorithm
  • GlueX+: Fixed a bug that prevent some hits from being considered, lowered energy threshold to "seed" cluster

Single photon event sample

Single photon efficiency (excluding events with tracking hits):

Energy resolution: GlueX: E res.AFTER0.png

GlueX+: E res.AFTER4.png

Timing resolution:

Single pion event sample

b1pi event sample