* We reviewed the [[Conference Call with Hamamatsu Representatives, January 5, 2012|Conference call with Hamamatsu representatives]] and the solution we have decided to pursue: 4 SMD-type 3×3 mm devices in a row. | * We reviewed the [[Conference Call with Hamamatsu Representatives, January 5, 2012|Conference call with Hamamatsu representatives]] and the solution we have decided to pursue: 4 SMD-type 3×3 mm devices in a row. | ||
− | * We reviewed the recently received [ | + | * We reviewed the recently received [http://www.jlab.org/Hall-D/procurements/start_counter_sipm/Quote%2328298,%20SMD%20MPPC.pdf quote from Hamamatsu] for the relevant devices. (See Mark for the username and password). |
− | * We looked at the latest drawings from Chuck, [ | + | * We looked at the latest drawings from Chuck, [https://halldweb1.jlab.org/detectors/start_counter/ITO_1_27_12.pptx 3-D close-up version] and [https://halldweb1.jlab.org/talks/2012-1Q/SC_LAYOUT_1_26_12.pdf line-drawing version] and discussed various mechanical considerations for the read-out design. |
==Prototype Report== | ==Prototype Report== | ||
− | * Werner has placed an order with | + | * Werner has placed an order with [http://www.mcnealplasticmachining.com/ McNeal] to make a sample counter. |
==Simulation Report== | ==Simulation Report== | ||
− | Puneet showed results recent results from [[ | + | Puneet showed results recent results from [[Start Counter Simulations|new studies that model light collection]] in the counters. He uses Geant4. He described: |
# Geometry and set-up | # Geometry and set-up | ||
# Material properties used | # Material properties used | ||
# Optical surface options explored | # Optical surface options explored | ||
Results are not inconsistent with what has been observed on the bench. See his wiki page for details. | Results are not inconsistent with what has been observed on the bench. See his wiki page for details. |
Revision as of 16:23, 10 February 2012
GlueX Start Counter Meeting
Thursday, February 9, 2012
10 am EST
JLab: CEBAF Center, Room F326
Contents
Agenda
- Announcements
- Review minutes from previous meeting
- Prototype Report
- SiPM configuration
- Contract Status
- Simulation Status
Communication Information
Video Conferencing
- ESNet: 8542553
- EVO:
- Meeting URL: http://evo.caltech.edu/evoNext/koala.jnlp?meeting=e9eIeivevnaeaBIsaaI9
- Phone Bridge ID: 11 7685
Slides
Talks can be deposited in the directory /group/halld/www/halldweb1/html/talks/2012-1Q
on the JLab CUE. This directory is accessible from the web at https://halldweb1.jlab.org/talks/2012-1Q/ .
Chair's Cell Phone
(757)504-0664
Minutes
Present:
- FIU: Werner Boeglin, Lei Guo, Puneet Khetarpal, Eric Pooser
- JLab: Eugene Chudakov, Chuck Hutton, Mark Ito (chair), Tim Whitlatch, Beni Zihlmann
SiPM configuration
- We reviewed the Conference call with Hamamatsu representatives and the solution we have decided to pursue: 4 SMD-type 3×3 mm devices in a row.
- We reviewed the recently received quote from Hamamatsu for the relevant devices. (See Mark for the username and password).
- We looked at the latest drawings from Chuck, 3-D close-up version and line-drawing version and discussed various mechanical considerations for the read-out design.
Prototype Report
- Werner has placed an order with McNeal to make a sample counter.
Simulation Report
Puneet showed results recent results from new studies that model light collection in the counters. He uses Geant4. He described:
- Geometry and set-up
- Material properties used
- Optical surface options explored
Results are not inconsistent with what has been observed on the bench. See his wiki page for details.