Difference between revisions of "BCAL reconstruction 8/24/11"
From GlueXWiki
Line 10: | Line 10: | ||
* KLOE algorithm: currently default | * KLOE algorithm: currently default | ||
* GlueX algorithm: by Matt Shepherd [[media:New_bcal_recon.pdf | "New" BCAL Reconstruction Algorithm]] | * GlueX algorithm: by Matt Shepherd [[media:New_bcal_recon.pdf | "New" BCAL Reconstruction Algorithm]] | ||
− | * GlueX+: Fixed a bug that prevented some DBCALPoint from being considered | + | * GlueX+: Fixed a bug that prevented some DBCALPoint from being considered; lowered energy threshold to seed cluster, minSeed, from 20 MeV to 10 Mev. |
==Single photon event sample== | ==Single photon event sample== | ||
Line 25: | Line 25: | ||
===Energy resolution=== | ===Energy resolution=== | ||
These plots use E_raw, not the corrected/calibrated E. They also exclude events with tracking hits. | These plots use E_raw, not the corrected/calibrated E. They also exclude events with tracking hits. | ||
+ | |||
+ | KLOE: | ||
GlueX: | GlueX: | ||
Line 36: | Line 38: | ||
===Timing resolution=== | ===Timing resolution=== | ||
+ | |||
+ | KLOE: | ||
+ | |||
+ | GlueX: | ||
+ | |||
+ | GlueX+: | ||
==Single pion event sample== | ==Single pion event sample== | ||
==b1pi event sample== | ==b1pi event sample== |
Revision as of 16:54, 24 August 2011
Contents
Summary
- BCAL reconstruction seemed to be an obstacle in b1pi events
- Two reconstruction algorithms in tree: KLOE algorithm=default, "new" algorithm by matt s.
- Found two issues which lead to poor energy resolution at low E (fixes not checked in yet)
- "New" algorithm seems to be doing well for single-photon events
- Further study of b1pi, etc.
- Further fine-tuning needed, but maybe should wait until BCAL segmentation finalized?
BCAL Reconstruction algorithms
- KLOE algorithm: currently default
- GlueX algorithm: by Matt Shepherd "New" BCAL Reconstruction Algorithm
- GlueX+: Fixed a bug that prevented some DBCALPoint from being considered; lowered energy threshold to seed cluster, minSeed, from 20 MeV to 10 Mev.
Single photon event sample
Single photon efficiency
Exclude all events with tracking hits (include only events where we actually expect to reconstruct a single)
KLOE: 99%
GlueX: 98.5%
GlueX+: 99.5%
Energy resolution
These plots use E_raw, not the corrected/calibrated E. They also exclude events with tracking hits.
KLOE:
GlueX:
GlueX+:
Timing resolution
KLOE:
GlueX:
GlueX+: