Difference between revisions of "BCAL reconstruction 8/24/11"
From GlueXWiki
Line 1: | Line 1: | ||
==BCAL Reconstruction algorithms== | ==BCAL Reconstruction algorithms== | ||
− | KLOE algorithm: currently default | + | * KLOE algorithm: currently default |
− | GlueX algorithm: by Matt Shepherd [[media:New_bcal_recon.pdf | "New" BCAL Reconstruction Algorithm]] | + | * GlueX algorithm: by Matt Shepherd [[media:New_bcal_recon.pdf | "New" BCAL Reconstruction Algorithm]] |
− | GlueX+: Fixed a bug that prevent some hits from being considered, lowered energy threshold to "see" cluster | + | * GlueX+: Fixed a bug that prevent some hits from being considered, lowered energy threshold to "see" cluster |
+ | ** Further fine-tuning pending BCAL readout segmentation decision? | ||
==Single photon event sample== | ==Single photon event sample== |
Revision as of 11:44, 24 August 2011
Contents
BCAL Reconstruction algorithms
- KLOE algorithm: currently default
- GlueX algorithm: by Matt Shepherd "New" BCAL Reconstruction Algorithm
- GlueX+: Fixed a bug that prevent some hits from being considered, lowered energy threshold to "see" cluster
- Further fine-tuning pending BCAL readout segmentation decision?
Single photon event sample
Single photon efficiency (excluding events with tracking hits): KLOE: 99% GlueX: 98.5% GlueX+: 99%
Energy resolution:
Timing resolution: