Difference between revisions of "Status of motor applications 05/01/2014"
From GlueXWiki
(Created page with "TEst") |
|||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | ||
+ | {| border="1" cellpadding="2" align="center" valign="top" | ||
+ | !width="150" | Application name | ||
+ | !width="50" | # of axes | ||
+ | !width="250" | Stage status | ||
+ | !width="200" | Cable status | ||
+ | !width="200" | Connectors | ||
+ | !width="150" | Software | ||
+ | !width="450" | Comments | ||
+ | |- | ||
+ | |- | ||
+ | | Goniometer || 5 || Tested || In production || Not installed || Partially ready || Wired in FEL | ||
+ | |- | ||
+ | | <span style="color: red;"> Microscope </span> || 3 || Not tested || Manufactured || Installed on stage || Does not exist || Ready for test in EEL, will go to UCONN | ||
+ | |- | ||
+ | | Amorphous radiator || 1 || Tested || Manufactured || Not installed || Partially ready || In the tagger hall, not wired | ||
+ | |- | ||
+ | | <span style="color: red;"> Collimator </span> || 1 || Installed, not surveyed, not tested || Manufactured || Not installed || Ready, needs survey || In the hall, not wired, needs to be wired | ||
+ | |- | ||
+ | | PS Converter || 1 || Not tested || Manufactured || Not installed || Partially ready || Not wired in FEL, limit switches need connectors | ||
+ | |- | ||
+ | | TAC || 1 || Does not exist || Partially Manufactured || Not installed || Does not exist || Need to make the stage | ||
+ | |- |
Latest revision as of 08:37, 1 May 2014
Application name | # of axes | Stage status | Cable status | Connectors | Software | Comments |
---|---|---|---|---|---|---|
Goniometer | 5 | Tested | In production | Not installed | Partially ready | Wired in FEL |
Microscope | 3 | Not tested | Manufactured | Installed on stage | Does not exist | Ready for test in EEL, will go to UCONN |
Amorphous radiator | 1 | Tested | Manufactured | Not installed | Partially ready | In the tagger hall, not wired |
Collimator | 1 | Installed, not surveyed, not tested | Manufactured | Not installed | Ready, needs survey | In the hall, not wired, needs to be wired |
PS Converter | 1 | Not tested | Manufactured | Not installed | Partially ready | Not wired in FEL, limit switches need connectors |
TAC | 1 | Does not exist | Partially Manufactured | Not installed | Does not exist | Need to make the stage |