|width="415pt"|[[Image:setup1.jpg|thumb|none|400px|Setup of the new prototype.]]
 
|width="415pt"|[[Image:setup1.jpg|thumb|none|400px|Setup of the new prototype.]]
 
|width="415pt"|[[Image:setup2.jpg|thumb|none|400px|Setup of the new prototype.]]
 
|width="415pt"|[[Image:setup2.jpg|thumb|none|400px|Setup of the new prototype.]]
|width="415pt"|[[Image:fe55spectrum.jpg|thumb|none|400px|Fe-55 induced energy spectrum.]]
 
 
|-
 
|-
 
|}
 
|}
 +
 +
= HV-plateau curve and Noise vs HV =
 +
{| border="1" cellpadding="2"
 +
|-
 +
|width="415pt"|[[Image:hv-curve.jpg|thumb|none|400px|Tracked cosmic rays vs HV (normalized).]]
 +
|width="415pt"|[[Image:noisevshv.jpg|thumb|none|400px|Pedestal mean vs HV.]]
 +
|-
 +
|}
 +
  
 
= Check if 125 MHz clock is working with a 300 MHz block pulse input =
 
= Check if 125 MHz clock is working with a 300 MHz block pulse input =

Revision as of 11:16, 9 March 2009

First Fe-55 spectrum

Setup of the new prototype.
Setup of the new prototype.

HV-plateau curve and Noise vs HV

Tracked cosmic rays vs HV (normalized).
Pedestal mean vs HV.


Check if 125 MHz clock is working with a 300 MHz block pulse input

Yes 125~MHz clock is correct.

Pedestal

The pedestal mean was between 993 and 1365 channels at Aug 2008 with all channels working. Now the pedestal mean is between 0 and 437 channels. This mean I have to move the baseline up a little bit...but the spread of the mean did not change.


Pedestals when the HVB is connected to the CDC

Pedestal vs time (1000 event runs) is plotted.

Pedestal vs time (ch1).
Pedestal vs time (ch2).
Pedestal cs time (ch3).


Channels 12-13-14 show some (signs of) problems:

Pedestal vs time (ch12).
Pedestal vs time (ch13).
Pedestal cs time (ch14).

Pedestals when HVB is not connected

Pedestal vs time (1000 event runs) is plotted.

Pedestal vs time (ch1).
Pedestal vs time (ch2).
Pedestal cs time (ch3).


Channels 12-13-14 show some (signs of) problems:

Pedestal vs time (ch12).
Pedestal vs time (ch13).
Pedestal cs time (ch14).


Old pedestals versus time (Aug 2008)

Pedestal vs time (ch1).
Pedestal vs time (ch2).
Pedestal cs time (ch3).

Some sample signals

Raw signal.
Raw signal.
Raw signal.


Energy spectra (not tracked)

Energy spectrum (ch1).
Energy spectrum (ch2).
Energy spectrum (ch16).


t-Zero spectra

T-zero spectrum (ch1).
T-zero spectrum (ch2).
T-zero spectrum (ch16).