Difference between revisions of "Photon Reconstruction in b1pi events 02/10/2012"

From GlueXWiki
Jump to: navigation, search
(Reconstructed photons)
(Reconstructed photons)
Line 46: Line 46:
 
After correcting these two issues:
 
After correcting these two issues:
  
[[...]]
+
[[Image:PhotonEvsTheta recon FCAL Feb12.aggressiveTrackMatching.png]]
  
We can make a timing cut (t_shower-t_flight) <
+
We can make a timing cut (t_shower-t_flight) < 1 ns:
 +
 
 +
[[..]]
  
 
===Timing===
 
===Timing===

Revision as of 12:21, 22 February 2012

BCAL

Thrown photons

Look at the distribution of decay photons from the pi0.

For comparison with reconstructed data, useful to look at z rather than theta. This is the z that the photon would reach the inner radius of the BCAL, given its momentum and vertex.

PhotonEvsZ thrown BCAL.png

PhotonZ thrown BCAL.png

Reconstructed photons

Spectrum of reconstructed "photons": exclude clusters that can be matched to a charged track.

PhotonEvsZ recon BCAL.png

PhotonZ recon BCAL.png

Where does each of these peaks come from?

  • Peaks at upstream and downstream ends of detector from noise that cause garbage timing info?
  • Other three sharp peaks? Look like FDC structure, but spacing is not right?

Cuts

  • A timing cut fabs(t_shower-t_flight) < 1 ns can be applied to remove many of the extra "photons". (Red curve below)
  • I don't think low energy showers are well understood at the moment, so remove clusters with E<60 MeV. (Green)
  • Also, cut out a problem area at forward angles and lower energies (E<120 MeV && z>325 cm) (Blue)

More work needed to optimize cuts.

PhotonZ recon cuts BCAL.png

With all cuts:

PhotonEvsZ recon cuts BCAL.png

Number of "photons" decreases from 44,000 to 13,000.

FCAL

Thrown photons

PhotonEvsTheta thrown FCAL Feb12.png

Reconstructed photons

PhotonEvsTheta recon FCAL Feb12.png

Way too many reconstructed. Clusters matched to charged tracks are vetoed, but this has some issues.

  • Only one matching FCAL cluster per track is allowed with the current code. Frequently hadronic showers are grouped into multiple clusters.
  • The match radius is hardcoded as 5 cm, but in the calib/PID/photon_track_matching this parameter is set to 15 cm.

After correcting these two issues:

PhotonEvsTheta recon FCAL Feb12.aggressiveTrackMatching.png

We can make a timing cut (t_shower-t_flight) < 1 ns:

[[..]]

Timing

t_shower-t_flight:

PhotonTproj recon FCAL.png

Not centered on 0???

Try to cut on timing info (tproj-2.3 < 1.4):

PhotonEvsTheta recon cuts FCAL Feb12.png

Too few.

Distribution doesn't match thrown.

Two gamma invariant Mass

Look at pairs of 2 BCAL photons, subject to cuts described above. Using truth vertex information.

Later should add FCAL photons.

Compare KLOE algorithm to GlueX algorithm.

Photon two gamma invariant mass 2BCAL.png

GlueX is in red, KLOE in black.