June 23, 2016 Transition Radiation Detector meeting

Recent TRD reports at the GlueX collaboration meeting

  1. Oct 2015
  2. Feb 2016
  3. May 2016

Prototype: requirements and very preliminary design

  1. Requirements:
    • Use existing FDC pre-amps, fADC125, connectors, cables
    • Wires and strips at 90 deg.;
    • One 24-channel pre-amp for the wires and one pre-amp for the strips.
    • Active area sizes:
      • 240 mm across wire direction: sense wire pitch of 10 mm
      • 120 mm across strip direction: strip pitch of 5 mm.
    • Field wires in between sense wires with 10 mm pitch.
    • 20 mm drift gap
    • Max drift time < 3 microseconds (to be used within the standard GlueX DAQ):
  2. 3D schematic