Minutes-6-23-2016

From GlueXWiki
Revision as of 11:55, 30 June 2016 by Pentchev (Talk | contribs)

Jump to: navigation, search

June 23, 2016 Transition Radiation Detector meeting

Recent TRD reports at the GlueX collaboration meeting

  1. Oct 2015
  2. Feb 2016
  3. May 2016

Prototype: requirements and very preliminary design

  1. Requirements:
    • Use existing FDC pre-amps, fADC125, connectors, cables
    • Wires and strips at 90 deg.;
    • One 24-channel pre-amp for the wires and one pre-amp for the strips.
    • Active area sizes:
      • 240 mm across wire direction: sense wire pitch of 10 mm
      • 120 mm across strip direction: strip pitch of 5 mm.
    • Field wires in between sense wires with 10 mm pitch.
    • 20 mm drift gap
    • Max drift time < 3 microseconds (to be used within the standard GlueX DAQ):
    • Xe/CO2 70/30 gas
    • Upstream cathode made of aluminized Mylar - critical to minimized keV-photon absorption
    • Radiator in front up to 150 mm thick - good to have it in a separate gas volume flushed with CO2, also to keep the upstream cathode flat and insulated.
  2. Detector schematic
  3. Brian's design