Line 19: Line 19:
 
#* 20 mm drift gap
 
#* 20 mm drift gap
 
#* Max drift time < 3 microseconds (to be used within the standard GlueX DAQ):
 
#* Max drift time < 3 microseconds (to be used within the standard GlueX DAQ):
#** ~2kV +HV on sense wires, -500V on field wires, -1.4kV on the upstream cathode [http://www.jlab.org/Hall-D/detector/trd/TRD_Garfield_NO_second_cathode.png Garfield field/drift time simulations]
+
#** +2kV on sense wires, -500V on field wires, -1.4kV on the upstream cathode, downstream cathode (with strips) on ground [http://www.jlab.org/Hall-D/detector/trd/TRD_Garfield_NO_second_cathode.png Garfield field/drift time simulations]
 +
#** Adding additional cathode separates the drift
 
# [http://www.jlab.org/Hall-D/detector/trd/Drawing1_Layout1.pdf 3D schematic]
 
# [http://www.jlab.org/Hall-D/detector/trd/Drawing1_Layout1.pdf 3D schematic]
  

Revision as of 11:20, 23 June 2016

June 23, 2016 Transition Radiation Detector meeting

Recent TRD reports at the GlueX collaboration meeting

  1. Oct 2015
  2. Feb 2016
  3. May 2016

Prototype: requirements and very preliminary design

  1. Requirements:
    • Use existing FDC pre-amps, fADC125, connectors, cables
    • Wires and strips at 90 deg.;
    • One 24-channel pre-amp for the wires and one pre-amp for the strips.
    • Active area sizes:
      • 240 mm across wire direction: sense wire pitch of 10 mm
      • 120 mm across strip direction: strip pitch of 5 mm.
    • Field wires in between sense wires with 10 mm pitch.
    • 20 mm drift gap
    • Max drift time < 3 microseconds (to be used within the standard GlueX DAQ):
      • +2kV on sense wires, -500V on field wires, -1.4kV on the upstream cathode, downstream cathode (with strips) on ground Garfield field/drift time simulations
      • Adding additional cathode separates the drift
  2. 3D schematic