Difference between revisions of "Mattione Update 12142011"
From GlueXWiki
(→Particle Overlay) |
|||
Line 23: | Line 23: | ||
| [[Image:Mattione_Update_12142011_MeandEdxVsP.gif|thumb|left|500px]] | | [[Image:Mattione_Update_12142011_MeandEdxVsP.gif|thumb|left|500px]] | ||
| [[Image:Mattione_Update_12142011_MeandEdxVsP_Zoom.gif|thumb|left|500px|Same plot, but zoomed in.]] | | [[Image:Mattione_Update_12142011_MeandEdxVsP_Zoom.gif|thumb|left|500px|Same plot, but zoomed in.]] | ||
+ | |} | ||
+ | |||
+ | == Confidence Levels == | ||
+ | |||
+ | * Confidence Levels for FDC/CDC dE/dx for protons, pions, and kaons: | ||
+ | {| class="wikitable" | ||
+ | | [[Image:Mattione_Update_12142011_ConfidenceLevel_Proton_FDC.gif|thumb|left|500px|Protons, FDC]] | ||
+ | | [[Image:Mattione_Update_12142011_ConfidenceLevel_Proton_CDC.gif|thumb|left|500px|Protons, CDC]] | ||
+ | |- | ||
+ | | [[Image:Mattione_Update_12142011_ConfidenceLevel_PiPlus_FDC.gif|thumb|left|500px|PiPlus, FDC]] | ||
+ | | [[Image:Mattione_Update_12142011_ConfidenceLevel_PiPlus_CDC.gif|thumb|left|500px|PiPlus, CDC]] | ||
+ | |- | ||
+ | | [[Image:Mattione_Update_12142011_ConfidenceLevel_KPlus_FDC.gif|thumb|left|500px|KPlus, FDC]] | ||
+ | | [[Image:Mattione_Update_12142011_ConfidenceLevel_KPlus_CDC.gif|thumb|left|500px|KPlus, CDC]] | ||
|} | |} |
Revision as of 12:23, 14 December 2011
K+'s
- FDC K+ dE/dx μ & σ
- σ is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
- CDC K+ dE/dx μ & σ
- σ is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
Particle Overlay
- dE/dx μ vs p for different particle types & CDC/FDC (error bar is overall σ (particles generated uniformly across θ & p))
- 2nd plot is zoomed in version of 1st plot
- Low momentum kaons overlap pions because they decayed: dE/dx χ2 not evaluated for kaons in this region.
Confidence Levels
- Confidence Levels for FDC/CDC dE/dx for protons, pions, and kaons: