== DC dE/dx Study Overview ==
 +
 
 +
=== Introduction ===
 
* DC dE/dx information used for PID is bad, is disabled until fixed.  
 
* DC dE/dx information used for PID is bad, is disabled until fixed.  
 
* DC dE/dx Confidence Level (for protons, similar for K+'s, &pi;<sup>+</sup>'s, and &pi;<sup>-</sup>).  
 
* DC dE/dx Confidence Level (for protons, similar for K+'s, &pi;<sup>+</sup>'s, and &pi;<sup>-</sup>).  
Line 5: Line 7:
 
<br style="clear:both;"/>
 
<br style="clear:both;"/>
  
=== Notes ===
+
=== Procedure ===
* CDC & FDC treated separately since they have different gas mixtures.  
+
* Look at reconstructed dE/dx in CDC & FDC (treated separately: different gas mixtures).
* Half of the track hits in each of the FDC/CDC (those with the largest dE/dx) are ignored.
+
** Half of the track hits in each of the FDC/CDC (those with the largest dE/dx) are ignored: truncates Landau distribution to resemble Gaussian distribution.
** Truncates Landau distribution to resemble Gaussian distribution.
+
* Will fit mean and &sigma; of these distributions and use them in calculation of &chi;<sup>2</sup>
  
 
== CDC &pi;<sup>+</sup>==
 
== CDC &pi;<sup>+</sup>==

Revision as of 13:05, 16 November 2011

DC dE/dx Study Overview

Introduction

  • DC dE/dx information used for PID is bad, is disabled until fixed.
  • DC dE/dx Confidence Level (for protons, similar for K+'s, π+'s, and π-).
protons


Procedure

  • Look at reconstructed dE/dx in CDC & FDC (treated separately: different gas mixtures).
    • Half of the track hits in each of the FDC/CDC (those with the largest dE/dx) are ignored: truncates Landau distribution to resemble Gaussian distribution.
  • Will fit mean and σ of these distributions and use them in calculation of χ2

CDC π+

  • Generated up to p = 9.0 GeV/c
  • CDC π+ dE/dx vs. βγ
CDC, π+


  • CDC π+ dE/dx Mean, Resolution vs. βγ
CDC, π+
CDC, π+


  • CDC π+ dE/dx Mean, Resolution in different dx Bins vs. βγ


FDC π+

  • Generated up to p = 9.0 GeV/c
  • FDC π+ dE/dx vs. βγ
FDC, π+


  • FDC π+ dE/dx Mean, Resolution vs. βγ
FDC, π+
FDC, π+


  • FDC π+ dE/dx Mean, Resolution in different dx Bins vs. βγ
FDC, π+
FDC, π+


CDC vs. FDC π+

  • CDC vs. FDC π+ dE/dx Mean, Resolution vs. βγ
π+
π+