Mattione Update 11162011

From GlueXWiki
Jump to: navigation, search

DC dE/dx Study Overview

Introduction

  • DC dE/dx information used for PID is bad, is disabled until fixed.
    • DC dE/dx Confidence Level (for protons, similar for K+'s, π+'s, and π-).
protons


Procedure

  • Look at reconstructed dE/dx in CDC & FDC (treated separately: different gas mixtures).
    • Half of the track hits in each of the FDC/CDC (those with the largest dE/dx) are ignored: truncates Landau distribution to resemble Gaussian distribution.
  • Will fit mean and σ of these distributions and use them in calculation of χ2

FDC π+

  • Generated up to p = 9.0 GeV/c
  • FDC π+ dE/dx vs. βγ
FDC, π+


  • FDC π+ dE/dx Mean, Resolution vs. βγ
FDC, π+
FDC, π+


  • FDC π+ dE/dx Mean, Resolution in different dx Bins vs. βγ
FDC, π+
FDC, π+


CDC π+

  • Generated up to p = 9.0 GeV/c
  • CDC π+ dE/dx vs. βγ
CDC, π+


  • CDC π+ dE/dx Mean, Resolution vs. βγ
CDC, π+
CDC, π+



CDC vs. FDC π+

  • CDC vs. FDC π+ dE/dx Mean, Resolution vs. βγ
π+
π+