* Strategy for equipment FCC noise specifications - Elliott
 
* Strategy for equipment FCC noise specifications - Elliott
 
* CDC thermocouples - Josh
 
* CDC thermocouples - Josh
* [https://halldweb1.jlab.org/wiki/images/6/6e/Hv_caen_201203.pdf HV Control] - Nerses
+
* [https://halldweb.jlab.org/wiki/images/6/6e/Hv_caen_201203.pdf HV Control] - Nerses
 
* Other EPICS - Hovanes, Nerses, Vanik
 
* Other EPICS - Hovanes, Nerses, Vanik
* [http://halldweb1.jlab.org/JInventory JInventory database] - Elliott
+
* [http://halldweb.jlab.org/JInventory JInventory database] - Elliott
 
* Counting house installation - Hovanes, Mark
 
* Counting house installation - Hovanes, Mark
 
* Equipment orders - Mark, Hovanes
 
* Equipment orders - Mark, Hovanes
Line 17: Line 17:
 
* PLC programming - Josh
 
* PLC programming - Josh
 
* Elogs and databases - Elliott
 
* Elogs and databases - Elliott
** [https://halldweb1.jlab.org/elog-halld Midas elog]
+
** [https://halldweb.jlab.org/elog-halld Midas elog]
 
** Operator elog
 
** Operator elog
 
* Experiment Control Supervisor - Elliott
 
* Experiment Control Supervisor - Elliott
* [http://halldweb1.jlab.org/mantisbt Mantis task tracker]
+
* [http://halldweb.jlab.org/mantisbt Mantis task tracker]
  
  
Line 75: Line 75:
  
 
* We are purchasing the previous generation of mainframes, not the ones just released.
 
* We are purchasing the previous generation of mainframes, not the ones just released.
* We are only using A1535 HV boards.
+
* We are only using A1535 HV boards or similar.
 
* This is a modified version of a package from CLS.
 
* This is a modified version of a package from CLS.
 
* Currently it can support 8 crates/IOC.
 
* Currently it can support 8 crates/IOC.

Latest revision as of 11:25, 31 March 2015

Agenda

  • Announcements
  • Minutes from previous meeting 8-Mar-2012
  • Ordering PXI system - Yi, Elliott
  • Strategy for equipment FCC noise specifications - Elliott
  • CDC thermocouples - Josh
  • HV Control - Nerses
  • Other EPICS - Hovanes, Nerses, Vanik
  • JInventory database - Elliott
  • Counting house installation - Hovanes, Mark
  • Equipment orders - Mark, Hovanes
  • Solenoid_Controls_Redesign - Mark, Josh, Scot, Yi, Elliott
    • UPS power, coil tap circuits, PXI, SOE, QD, shunt replacement, ground fault detector, etc.
  • Test stand - Hovanes, Josh
  • Target, goniometer, other new systems
  • PLC programming - Josh
  • Elogs and databases - Elliott
  • Experiment Control Supervisor - Elliott
  • Mantis task tracker


Time/Location

9:30 AM Thurs 22-Mar-2012 CC L207


Announcements

Next Meeting

9:30am 4-Apr-2012 CC L207


Minutes

Present: Elliott W, Mark S, Scot S, Josh B, Hovanes E, Nerses G, Vanik K.


Ordering PXI System

Yi is ready to order, he just needs something close to the final channel counts.


FCC Noise Specs

The current strategy as I understand it is that FCC Class A equipment is acceptable but that Fernando wants to know what's going into the hall. Mark will continue to send Fernando information about our controls equipment. If noise is suspected then we will measure and mitigate. I suspect some of the equipment in the hall does not even meet FCC Class A. We are still discussing sending UPS power from the counting house to the hall.


CDC Thermocouples

Josh and Naomi have resolved this. CMU will purchase Type T thermocouples, and Josh ordered a matching Point I/O module and a thermocouple for evaluation.


JInventory

Elliott was about to deploy when everyone in the room noted that the interfaces really need to appear in pulldown menus sourcing a table of possible interfaces. Elliott will add this feature and hopes to get it out next week.


CAEN HV

Nerses gave a complete report on the status of CAEN HV control in EPICS, see his talk above.

  • We are purchasing the previous generation of mainframes, not the ones just released.
  • We are only using A1535 HV boards or similar.
  • This is a modified version of a package from CLS.
  • Currently it can support 8 crates/IOC.
  • EPICS databases are automatically generated.
  • Nerses is working on both expert and operator gui's.


At this point we got kicked out of the room...