# Energy assignment
 
# Energy assignment
 
#* GlueX: We have a total of 102  microscope channels covering the energy range from 8.2 - 9.2 GeV for a 12 GeV beam. (The energy numbers need to be scaled for other electron beam energies).
 
#* GlueX: We have a total of 102  microscope channels covering the energy range from 8.2 - 9.2 GeV for a 12 GeV beam. (The energy numbers need to be scaled for other electron beam energies).
#* CPP: We only have 96 microscope channels (last bundle of 6 does not fit), covering the energy range of 4.7 - 6.2 GeV for a 12 GeV beam. I assume that the software will retain 102 channels but the last channels should never show hits.
+
#* CPP: We only have 96 microscope channels (last bundle of 6 does not fit), covering the energy range of 4.5 - 6.0 GeV for a 11.57 GeV beam. I assume that the software will retain 102 channels but the last channels should never show hits.
#* The hodoscope counter numbers in the array closest to the focal plane (x=-8 cm) are 222 (E=6.179 GeV) and 246 (E=4.738 GeV).  
+
#* The hodoscope counter numbers in the array closest to the focal plane (x=-8 cm) are 222 (E=5.95 GeV) and 246 (E=4.52 GeV).  
#* [https://halldweb.jlab.org/cgi-bin/ccdb/show_request?request=/PHOTON_BEAM/microscope/scaled_energy_range:100000:default:2022-04-07_17-25-44 CCDB entry for microscope].
+
#* [https://halldweb.jlab.org/cgi-bin/ccdb/show_request?request=/PHOTON_BEAM/microscope/scaled_energy_range:100000:default:2022-04-07_17-25-44 Scaled energy rage in CCDB entry for microscope].
 +
#* [https://halldweb.jlab.org/cgi-bin/ccdb/show_request?request=/PHOTON_BEAM/hodoscope/scaled_energy_range:100000:default:2022-05-11_17-26-44 Scaled energy range in CCDB entry for hodoscope].

Latest revision as of 10:32, 30 August 2023

  1. Description of move
  2. Schematics of the microscope move (Elton)
  3. Energy assignment
    • GlueX: We have a total of 102 microscope channels covering the energy range from 8.2 - 9.2 GeV for a 12 GeV beam. (The energy numbers need to be scaled for other electron beam energies).
    • CPP: We only have 96 microscope channels (last bundle of 6 does not fit), covering the energy range of 4.5 - 6.0 GeV for a 11.57 GeV beam. I assume that the software will retain 102 channels but the last channels should never show hits.
    • The hodoscope counter numbers in the array closest to the focal plane (x=-8 cm) are 222 (E=5.95 GeV) and 246 (E=4.52 GeV).
    • Scaled energy rage in CCDB entry for microscope.
    • Scaled energy range in CCDB entry for hodoscope.