Difference between revisions of "CPP-NPP Experimental Controls"
From GlueXWiki
(→Power HV/LV) |
|||
Line 3: | Line 3: | ||
== Power HV/LV == | == Power HV/LV == | ||
* HV for muon chambers: 6 HV channels for the 6 wire chambers (+1765V nominal) | * HV for muon chambers: 6 HV channels for the 6 wire chambers (+1765V nominal) | ||
− | * LV for muon chanbers: 6 times +5V and 6 times -5V (nominal current | + | * LV for muon chanbers: 6 times +5V and 6 times -5V (nominal current 1 mA per side per +/- 5V -> 4 A/ MWPC) |
* HV for 4 scintillator paddles: 8 HV channels for PMTs (-1800V nomial) | * HV for 4 scintillator paddles: 8 HV channels for PMTs (-1800V nomial) | ||
** HV main frame location (existing?)? | ** HV main frame location (existing?)? |
Revision as of 17:17, 9 November 2021
CPP requirements
Power HV/LV
- HV for muon chambers: 6 HV channels for the 6 wire chambers (+1765V nominal)
- LV for muon chanbers: 6 times +5V and 6 times -5V (nominal current 1 mA per side per +/- 5V -> 4 A/ MWPC)
- HV for 4 scintillator paddles: 8 HV channels for PMTs (-1800V nomial)
- HV main frame location (existing?)?
- LV main frame location (existing?)?
Chamber Gas
- Ar/CO2 (90%/10%) premixed in bottles
- gas line from gas shed to downstream platform
- gas manifold on downstream platform
- gas flow control though manual rota-meter (flow meter): nominal flow 300 sccm
- gas flow exhaust protected with oil bubblers
Chamber cooling
- under discussion, potentially with dry nitrogen
- no sensory foreseen, neither for flow nor for temperature.
DAQ readout
- CDC VXS crate \#1 is used with all fADC125s, moved to downstream platform
- needs new ROC (never used before in Gluex == new/unknown to GlueX mac/ip address)
- needs 2 Ethernet connections one for the fan-tray (slow control network) one for the ROC (DAQ network)
- needs 1 fiber optics connection to TI
- One fADC250 for scintillator digitization. Added to TOF crate?
Software
- GUI for HV/LV control, values to EPICS data base, for muon chamber and scintillators
- low level monitoring histograms, scaler display, for muon chamber and scintillators