Difference between revisions of "CDC and FDC readout tests"

From GlueXWiki
Jump to: navigation, search
(Created page with "The goal is to take CDC data using the FDC amplitude mode (FDC_amp_short) which is data type 9, I’ll have to check which mode # includes that. The reason for this is that...")
 
Line 1: Line 1:
The goal is to take CDC data using the FDC amplitude mode (FDC_amp_short) which is data type 9, I’ll have to check which mode # includes that.
+
The goal is to take CDC data using the FDC amplitude mode (FDC_amp_short) which is data type 9, included in mode 5.
  
 
The reason for this is that we switched from using pulse integral to amplitude for the CDC dE/dx, and using the FDC_amp_short mode will give us an extra 3 bits to read out amplitude and an extra 2 for pedestal, but not read out the integral.  
 
The reason for this is that we switched from using pulse integral to amplitude for the CDC dE/dx, and using the FDC_amp_short mode will give us an extra 3 bits to read out amplitude and an extra 2 for pedestal, but not read out the integral.  
Line 6: Line 6:
  
 
*With beam, at the beginning of the run period:
 
*With beam, at the beginning of the run period:
*10 evio files (max 1h) in FDC_amp_short with abit=pbit=0 (no scaling down)
+
*10 evio files (max 1h) in FDC_amp_short (mode 5) with abit=pbit=0 (no scaling down)
*10 evio files (max 1h) in CDC_short        
+
*10 evio files (max 1h) in CDC_short (mode 3)       
 
*Runs must be done in the same conditions (weather & beam intensity). 1h per mode is assumed, but if things go well  it will only take 10 mins .
 
*Runs must be done in the same conditions (weather & beam intensity). 1h per mode is assumed, but if things go well  it will only take 10 mins .
*Then for the rest of the run we should use FDC_amp_short.   
+
*Then for the rest of the run we should use FDC_amp_short (mode 5).   
  
 
Naomi will look at the test data (the 1h of each mode as above). If there is any problem with it, we can switch back to CDC_short.
 
Naomi will look at the test data (the 1h of each mode as above). If there is any problem with it, we can switch back to CDC_short.

Revision as of 08:53, 30 November 2017

The goal is to take CDC data using the FDC amplitude mode (FDC_amp_short) which is data type 9, included in mode 5.

The reason for this is that we switched from using pulse integral to amplitude for the CDC dE/dx, and using the FDC_amp_short mode will give us an extra 3 bits to read out amplitude and an extra 2 for pedestal, but not read out the integral.

Plan:

  • With beam, at the beginning of the run period:
  • 10 evio files (max 1h) in FDC_amp_short (mode 5) with abit=pbit=0 (no scaling down)
  • 10 evio files (max 1h) in CDC_short (mode 3)
  • Runs must be done in the same conditions (weather & beam intensity). 1h per mode is assumed, but if things go well it will only take 10 mins .
  • Then for the rest of the run we should use FDC_amp_short (mode 5).

Naomi will look at the test data (the 1h of each mode as above). If there is any problem with it, we can switch back to CDC_short.