Line 3: | Line 3: | ||
*** Uses threshold crossing time rather than FPGA-ish algorithm | *** Uses threshold crossing time rather than FPGA-ish algorithm | ||
*** Resolution is too poor | *** Resolution is too poor | ||
− | ** mcsmear doesn't | + | ** mcsmear doesn't seem to smear data enough |
*** TDC timing resolution is too good | *** TDC timing resolution is too good | ||
*** single photo-electron peaks in energy spectrum | *** single photo-electron peaks in energy spectrum |
Revision as of 15:53, 28 March 2013
- Simulation (mcsmear)
- fADC timing
- Uses threshold crossing time rather than FPGA-ish algorithm
- Resolution is too poor
- mcsmear doesn't seem to smear data enough
- TDC timing resolution is too good
- single photo-electron peaks in energy spectrum
- spikes in time histogram at low energy
- max ADC amplitude (12 bits?)
- Sampling fluctuations not applied on per-particle basis
- fADC timing
- Timewalk corrections
- Establish procedure for doing these corrections based on simulated data (how closely should this match the correction procedure for real data?)
- Determine form of timewalk corrections
- What if we have TDC info only on one end?