*# Check widths of energy distributions using low threshold and compare with expected (??)
 
*# Check widths of energy distributions using low threshold and compare with expected (??)
 
*:
 
*:
 +
* [[Media:20110602_bcal.pdf|BCAL Thresholds]] (David L.)
  
 
=Minutes=
 
=Minutes=

Revision as of 10:46, 2 June 2011

Meeting Info

Time:

  • 11:30 JLab
  • 9:30 Regina

Location:

  • CC F326-327

Vid-con:

  • ESNet 8542553

Agenda

  • Review action items from previous meeting
    1. Confirm Sampling fraction number for BCAL (Zisis)
      • Done. Latest number from Stamatis' thesis is 9.5%
      • New number has been committed to calib directory in svn
    2. Decide on proper form of energy correction and recalibrate BCAL GlueX-doc-1301, Plot (Andrei)
    3. Check on status of SiPM cross-talk/after pulse separation (David)
      • Recent value of 15.7% reported for 1μs pulse
      • Spoke with Yi. Earlier measurements indicated ~12% for a 200ns gate.
      • Estimate for 100ns gate may be closer to 10% according to Yi's guess.
    4. Investigate addition to pedestal width due to gain variation of SiPMs in an array (David)
      • Yi pointed out that this will affect the signal width, not the pedestal width.
      • The measured gain variation between tiles is ~4%. Adding this in quadrature increases single PE signal width from 10% to <11%
    5. Update calibDB with most recent values for SiPM and BCAL properties (David)
      • Done 5/31/2011.
    6. Write up and distribute document describing how BCAL threshold is calculated based on event size (David)
    7. Check widths of energy distributions using low threshold and compare with expected (??)
  • BCAL Thresholds (David L.)

Minutes

Participants

TBD

Action Items