Difference between revisions of "ASIC design optimizations"

From GlueXWiki
Jump to: navigation, search
m (Planned tests)
m (Planned tests)
Line 1: Line 1:
 
== Planned tests ==
 
== Planned tests ==
  
* High Voltage plateau
+
* High Voltage plateau   ===  done
 
Gas: Ar-CO2 87%-13% gas mixture.
 
Gas: Ar-CO2 87%-13% gas mixture.
 
Setup: the signal after the shaper was inverted and fed to a discriminator. The HV was changed and the signals above threshold where counted (normalized to 100s measure time).
 
Setup: the signal after the shaper was inverted and fed to a discriminator. The HV was changed and the signals above threshold where counted (normalized to 100s measure time).
Line 7: Line 7:
 
[[Image:hvplateau_ch15.jpg|thumb|none|400px|HV-curve,the count is normalized to 100s measurements.]]
 
[[Image:hvplateau_ch15.jpg|thumb|none|400px|HV-curve,the count is normalized to 100s measurements.]]
  
 +
Below galleries of pulses are shown for different HV:
 +
** 1600 V
  
  

Revision as of 15:47, 30 April 2008

Planned tests

  • High Voltage plateau === done

Gas: Ar-CO2 87%-13% gas mixture. Setup: the signal after the shaper was inverted and fed to a discriminator. The HV was changed and the signals above threshold where counted (normalized to 100s measure time). The result:

HV-curve,the count is normalized to 100s measurements.

Below galleries of pulses are shown for different HV:

    • 1600 V


  • (absolute) Gas gain as a function of High Voltage

Source measurement using Sr-90 (e-) or 55-Fe (X-rays) (if we have it) / or using cosmic rays? -- Estimated time: 1 day -- if we have a good source


  • Dynamic range + amplitude distributions

1 week measure with horizontal chamber + 1 week measure with tilted chamber. For amplitude distributions we need to have modified shapers. -- Estimated time: 2 weeks


  • Collection of gallery of pulses

I found 4 pulse galleries, measured directly after the pre-amplifier made by Gerard when he was here, they are shown below:

Gallery of pulses measured after the pre-amplifier
Gallery of pulses measured after the pre-amplifier
Gallery of pulses measured after the pre-amplifier
Gallery of pulses measured after the pre-amplifier