* Collection of gallery of pulses
 
* Collection of gallery of pulses
I found 4 pulse galleries made by Gerard when he was here, they are shown below:
+
I found 4 pulse galleries, measured directly after the pre-amplifier made by Gerard when he was here, they are shown below:
 +
[[Image:pulsegallery1.jpg|thumb|none|400px|Gallery of pulses measured after the pre-amplifier]]
 +
[[Image:pulsegallery2.jpg|thumb|none|400px|Gallery of pulses measured after the pre-amplifier]]
 +
[[Image:pulsegallery3.jpg|thumb|none|400px|Gallery of pulses measured after the pre-amplifier]]
 +
[[Image:pulsegallery4.jpg|thumb|none|400px|Gallery of pulses measured after the pre-amplifier]]
 +
 
 +
The conclusion was that the gain was too high.

Revision as of 15:22, 14 April 2008

Planned tests

  • High Voltage plateau

We will plot the cosmic count rate as a function of HV. We will do this using the Ar-CO2 87%-13% gas mixture. -- Estimated time: 1 day


  • (absolute) Gas gain

Source measurement using Sr-90 (e-) or 55-Fe (X-rays) (if we have it) == or using cosmic rays? -- Estimated time: 1 day


  • Dynamic range + amplitude distributions

1 week measure with horizontal chamber + 1 week measure with tilted chamber For amplitude distributions we need to have modified shapers. -- Estimated time: 2 weeks


  • Collection of gallery of pulses

I found 4 pulse galleries, measured directly after the pre-amplifier made by Gerard when he was here, they are shown below:

Gallery of pulses measured after the pre-amplifier
Gallery of pulses measured after the pre-amplifier
Gallery of pulses measured after the pre-amplifier
Gallery of pulses measured after the pre-amplifier

The conclusion was that the gain was too high.