Difference between revisions of "Online Monitoring Data Validation"
From GlueXWiki
(→Reference Plots) |
|||
Line 18: | Line 18: | ||
* '''Occupancy''' | * '''Occupancy''' | ||
− | |||
** Check CDC Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__CDC_occupancy.png link] ] | ** Check CDC Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__CDC_occupancy.png link] ] | ||
− | |||
− | |||
− | |||
** Check FDC Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__FDC_occupancy.png link] ] | ** Check FDC Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__FDC_occupancy.png link] ] | ||
+ | ** Check FCAL Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__FCAL_occupancy.png link] ] | ||
+ | ** Check BCAL Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__BCAL_occupancy.png link] ] | ||
** Check PS Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__PS_occupancy.png link] ] | ** Check PS Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__PS_occupancy.png link] ] | ||
** Check RF/TPOL Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__RF_TPOL_occupancy.png link] ] | ** Check RF/TPOL Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__RF_TPOL_occupancy.png link] ] | ||
Line 30: | Line 28: | ||
** Check TOF Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__TOF_occupancy.png link] ] | ** Check TOF Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__TOF_occupancy.png link] ] | ||
** Check Digihit Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DigiHits_occupancy.png link] ] | ** Check Digihit Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DigiHits_occupancy.png link] ] | ||
+ | ** Check DIRC South Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DIRC_occupancy.png link] ] | ||
+ | ** Check DIRC North Occupancy - Reference: [ [https://halldweb.jlab.org/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DIRC_North_occupancy.png link] ] | ||
<div class="toccolours mw-collapsible mw-collapsed"> | <div class="toccolours mw-collapsible mw-collapsed"> | ||
Line 38: | Line 38: | ||
<html> | <html> | ||
− | |||
<p><a href="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__CDC_occupancy.png "><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__CDC_occupancy.png" height="400"/></a></p> | <p><a href="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__CDC_occupancy.png "><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__CDC_occupancy.png" height="400"/></a></p> | ||
<p>CDC Occupancy: There should be a uniform decrease in intensity from the center of the detector outward. Random white cells scattered throughout occur when not enough data were collected, eg empty target runs, trigger tests or no beam. Several contiguous white, dark blue or bright yellow cells which don't match the neighboring cells are a problem.<br/> <br/></p> | <p>CDC Occupancy: There should be a uniform decrease in intensity from the center of the detector outward. Random white cells scattered throughout occur when not enough data were collected, eg empty target runs, trigger tests or no beam. Several contiguous white, dark blue or bright yellow cells which don't match the neighboring cells are a problem.<br/> <br/></p> | ||
+ | <p><a href="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__BCAL_occupancy.png "><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__BCAL_occupancy.png" height="400"/></a></p> | ||
<p><a href="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DIRC_North_occupancy.png "><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DIRC_North_occupancy.png" height="400"/></a></p> | <p><a href="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DIRC_North_occupancy.png "><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DIRC_North_occupancy.png" height="400"/></a></p> | ||
<p><a href="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DIRC_occupancy.png "><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DIRC_occupancy.png" height="400"/></a></p> | <p><a href="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DIRC_occupancy.png "><img src="/work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots/__DIRC_occupancy.png" height="400"/></a></p> |
Revision as of 09:38, 7 August 2020
This page contains offsite online monitoring procedures for Spring 2020.
Contents
Procedures
- An email is sent out twice per day, at 5 AM and 5 PM, JLab time (but only if you are on the mailing list, send Keigo a request to be put on that list.)
- Monitors should create a log entry that includes the run range of plots you examined and any discrepancies that you noted.
- Please focus on the discrepancies in your log entry, for example a short statement that "Everything looks OK, except the following:" is preferred.
- If discrepancies exist, please notify the run coordinator with your log post. Current run coordinator: X
- Monitors are welcome to check monitoring results more often, but are only expected to check the monitoring results when they receive the monitoring email, i.e., once per shift.
Reference Plots
Plots stored in: /work/halld2/data_monitoring/RunPeriod-2019-11/online_reference_plots
Click "Expand" to see the reference plots on this page.
- Occupancy
- Check CDC Occupancy - Reference: [ link ]
- Check FDC Occupancy - Reference: [ link ]
- Check FCAL Occupancy - Reference: [ link ]
- Check BCAL Occupancy - Reference: [ link ]
- Check PS Occupancy - Reference: [ link ]
- Check RF/TPOL Occupancy - Reference: [ link ]
- Check ST Occupancy - Reference: [ link ]
- Check TAGGER Occupancy - Reference: [ link ]
- Check TOF Occupancy - Reference: [ link ]
- Check Digihit Occupancy - Reference: [ link ]
- Check DIRC South Occupancy - Reference: [ link ]
- Check DIRC North Occupancy - Reference: [ link ]
Occupancy Reference Plots
CDC Occupancy: There should be a uniform decrease in intensity from the center of the detector outward. Random white cells scattered throughout occur when not enough data were collected, eg empty target runs, trigger tests or no beam. Several contiguous white, dark blue or bright yellow cells which don't match the neighboring cells are a problem.
- Hits and Reconstruction
- Check DIRC Digihits - Reference: [ link ]
- Check DIRC Hits - Reference: [ link ]
- Check Photon Beam Recon. - Reference: [ link ]
- Check Kinematics - Reference: [ link ]
- Check Num High Level Objects - Reference: [ link ]
- Check Reconstructed Reactions - Reference: [ link ]
- Check Trigger - Reference: [ link ]
- Check Vertex - Reference: [ link ]
- Timing
- Check Calorimeter Timing - Reference: [ link ]
- Check PID Timing - Reference: [ link ]
- Check Tracking Timing - Reference: [ link ]
- Check Tagger Timing - Reference: [ link ]
- Check Track Matched Timing - Reference: [ link ]
- Check Detector/RF Alignment - Reference: [ link ]
- Check Tagger/RF Alignment - Reference: [ link ]