Difference between revisions of "HDGeant4 Meeting, June 16, 2020"
From GlueXWiki
(→Richard's Action Item Review) |
|||
(4 intermediate revisions by the same user not shown) | |||
Line 29: | Line 29: | ||
* [https://github.com/JeffersonLab/HDGeant4/issues/152 Issue #152]: BCAL Photon Gun Updates. This issue has been closed. | * [https://github.com/JeffersonLab/HDGeant4/issues/152 Issue #152]: BCAL Photon Gun Updates. This issue has been closed. | ||
* [https://github.com/JeffersonLab/HDGeant4/issues/149 Issue #149]: BCAL structure in E/p distributions for kaons. This issue has been closed. | * [https://github.com/JeffersonLab/HDGeant4/issues/149 Issue #149]: BCAL structure in E/p distributions for kaons. This issue has been closed. | ||
− | * [https://github.com/JeffersonLab/HDGeant4/issues/143 Issue #143]: BCAL reconstructed energy sometimes broken on startup: multicore only. | + | * [https://github.com/JeffersonLab/HDGeant4/issues/143 Issue #143]: BCAL reconstructed energy sometimes broken on startup: multicore only. Richard has been able to reproduce the problem of significantly different BCAL energy distributions on repeated runs of HDGeant4 with a 2 GeV photon particle gun at 60 degrees. This appears to only happen when hdgeant4 is run in multi-threaded mode. We generally build hdgeant4 against a multi-threaded build of Geant4, but even so, single-threaded mode for hdgeant4 seems not to be a problem. Richard noted that our running on the OSG is always single-threaded. Now that he can reproduced the problem, he will turn to its solution. |
− | + | ||
* [https://github.com/JeffersonLab/HDGeant4/issues/111 Issue #111]: Difference in Acceptance between G3 and G4. Richard has produced a branch, bcal_nolight_heavy_rtj, where anything heavier than a proton will not produce visible energy. Colin will repeat the studies he presented last time with this branch and compare. | * [https://github.com/JeffersonLab/HDGeant4/issues/111 Issue #111]: Difference in Acceptance between G3 and G4. Richard has produced a branch, bcal_nolight_heavy_rtj, where anything heavier than a proton will not produce visible energy. Colin will repeat the studies he presented last time with this branch and compare. | ||
* [https://github.com/JeffersonLab/HDGeant4/issues/93 Issue #93]: Calorimeter timing mismatch between g3 and g4. This issue still needs to be closed and linked to Issue #111. | * [https://github.com/JeffersonLab/HDGeant4/issues/93 Issue #93]: Calorimeter timing mismatch between g3 and g4. This issue still needs to be closed and linked to Issue #111. | ||
− | == Richard's Action Item Review == | + | === Richard's Action Item Review === |
# Richard encouraged us to get started on preparations to advance to latest Geant4 release G4.10.06. Mark will build a version set, based on this release, and let Sean et al. know so they can do some comparative studies before we unleash the new release on the collaboration. | # Richard encouraged us to get started on preparations to advance to latest Geant4 release G4.10.06. Mark will build a version set, based on this release, and let Sean et al. know so they can do some comparative studies before we unleash the new release on the collaboration. | ||
Line 41: | Line 40: | ||
# Investigation of the backward kaon efficiency step at 120 degrees. There has been some progress on [https://github.com/JeffersonLab/halld_recon/issues/378 halld_recon Issue #378]. See the issue for details. | # Investigation of the backward kaon efficiency step at 120 degrees. There has been some progress on [https://github.com/JeffersonLab/halld_recon/issues/378 halld_recon Issue #378]. See the issue for details. | ||
# New HDGeant4 branch "bcal_nolight_heavy_rtj" for suppressing scintillation by heavy particles in the bcal, discussed above. | # New HDGeant4 branch "bcal_nolight_heavy_rtj" for suppressing scintillation by heavy particles in the bcal, discussed above. | ||
− | # | + | # "Yet to come": investigation of the 12% drop in preselection efficiency with CUTS card seen by George in etaprime,p |
− | == Action Item Review == | + | === Action Item Review === |
# Build a version set with Geant4 10.06.04. | # Build a version set with Geant4 10.06.04. | ||
# Merge issue #93 with #111. | # Merge issue #93 with #111. |
Latest revision as of 16:21, 30 June 2020
HDGeant4 Meeting
Tuesday, June 16, 2020
3:00 pm EDT
BlueJeans: 968 592 007
Contents
Agenda
- Review of minutes from the last Meeting (all)
- Issues on GitHub
- Pull Requests on GitHub
- Action Item Review
- preparations to advance to latest Geant4 release G4.10.06
- 20% reduction in cpu time from recent fix to tracking
- investigation of the multi-threaded bcal photon gun anomaly
- investigation of the backward kaon efficiency step at 120 degrees
- new HDGeant4 branch "bcal_nolight_heavy_rtj" for suppressing scintillation by heavy particles in the bcal
- yet to come - investigation of the 12% drop in preselection efficiency with CUTS card seen by George in etaprime,p
Minutes
Present: Sean Dobbs, Sergey Furletov, Colin Gleason, Mark Ito (chair), Igal Jaegle, Naomi Jarvis, Richard Jones, Susan Schadmand, Simon Taylor, Nilanga Wickramaarachchi, Beni Zihlmann
There is a recording of this meeting on the BlueJeans site. Use your JLab credentials to get access.
Review of minutes from the last Meeting
We went over the minutes from June 2.
- Issue #152: BCAL Photon Gun Updates. This issue has been closed.
- Issue #149: BCAL structure in E/p distributions for kaons. This issue has been closed.
- Issue #143: BCAL reconstructed energy sometimes broken on startup: multicore only. Richard has been able to reproduce the problem of significantly different BCAL energy distributions on repeated runs of HDGeant4 with a 2 GeV photon particle gun at 60 degrees. This appears to only happen when hdgeant4 is run in multi-threaded mode. We generally build hdgeant4 against a multi-threaded build of Geant4, but even so, single-threaded mode for hdgeant4 seems not to be a problem. Richard noted that our running on the OSG is always single-threaded. Now that he can reproduced the problem, he will turn to its solution.
- Issue #111: Difference in Acceptance between G3 and G4. Richard has produced a branch, bcal_nolight_heavy_rtj, where anything heavier than a proton will not produce visible energy. Colin will repeat the studies he presented last time with this branch and compare.
- Issue #93: Calorimeter timing mismatch between g3 and g4. This issue still needs to be closed and linked to Issue #111.
Richard's Action Item Review
- Richard encouraged us to get started on preparations to advance to latest Geant4 release G4.10.06. Mark will build a version set, based on this release, and let Sean et al. know so they can do some comparative studies before we unleash the new release on the collaboration.
- Richard has discovered 20% reduction in cpu time from killing particles that go beyond the walls, floor, and ceiling of the Hall in the simulation.
- Investigation of the multi-threaded bcal photon gun anomaly, discussed above.
- Investigation of the backward kaon efficiency step at 120 degrees. There has been some progress on halld_recon Issue #378. See the issue for details.
- New HDGeant4 branch "bcal_nolight_heavy_rtj" for suppressing scintillation by heavy particles in the bcal, discussed above.
- "Yet to come": investigation of the 12% drop in preselection efficiency with CUTS card seen by George in etaprime,p
Action Item Review
- Build a version set with Geant4 10.06.04.
- Merge issue #93 with #111.