Talks can be deposited in the directory <code>/group/halld/www/halldweb1/html/talks/2011-2Q</code> on the JLab CUE. This directory is accessible from the web at https://halldweb1.jlab.org/talks/2011-2Q/ . | Talks can be deposited in the directory <code>/group/halld/www/halldweb1/html/talks/2011-2Q</code> on the JLab CUE. This directory is accessible from the web at https://halldweb1.jlab.org/talks/2011-2Q/ . | ||
+ | |||
+ | =Minutes= | ||
+ | |||
+ | New Note 64 | ||
+ | |||
+ | • call paul | ||
+ | • sasha | ||
+ | • elton, tim, mark, simon | ||
+ | • caen tdc | ||
+ | ∘ starting with measurements with CAEN | ||
+ | ∘ see what kind of resolution for two long counters | ||
+ | ∘ f1 TDC | ||
+ | |||
+ | • proposal is to use leading edge | ||
+ | • athens uses led, does not excite scint | ||
+ | • hall d has two planes | ||
+ | • constrained: 4 measurements, 3 quantities: x, y, t | ||
+ | • note studies a method for extracting time walk corrections |
Revision as of 09:37, 18 April 2011
Contents
Location, Time
Friday, April 15, 2011
2:00 pm EDT
JLab: CEBAF Center, Room F326
Agenda
- Announcements
- Minutes from the last meeting
- Prototype Status [1]
- Contract Status
Communication
Videoconference
- ESNet: 8542553
- EVO: EVO site
- direct meeting link
- Phone Bridge ID: 8 9450
Telephone
- dial:
- US and Canada: (866)740-1260 (toll free)
- International: (303)248-0285 (toll call) or look up toll-free number at http://www.readytalk.com/intl
- enter access code followed by the # sign: 3421244#
Slides
Talks can be deposited in the directory /group/halld/www/halldweb1/html/talks/2011-2Q
on the JLab CUE. This directory is accessible from the web at https://halldweb1.jlab.org/talks/2011-2Q/ .
Minutes
New Note 64
• call paul • sasha • elton, tim, mark, simon • caen tdc ∘ starting with measurements with CAEN ∘ see what kind of resolution for two long counters ∘ f1 TDC
• proposal is to use leading edge • athens uses led, does not excite scint • hall d has two planes • constrained: 4 measurements, 3 quantities: x, y, t • note studies a method for extracting time walk corrections