RunPeriod-2016-02 Validation

From GlueXWiki
Jump to: navigation, search

Problems/Features

  • Will M. reported that the following runs with configuration TRG_FCAL_BCAL_short_b20.conf don't have access to the front panel triggers word, so non-production triggers can't be rejected by looking at the trigger words: 10331,10332,10346,10347,10348,10349,10351,10354
  • TAGH TDC hole: 10657 - 10720 (ADCs are fine)
  • 4 missing CDC LV channels, efficiency drop near phi = 0: 11071 - 11346
  • Solenoid changed in production to 1350A starting in 11580
  • RF period changed in production to 2 ns starting 11556
  • TAGM bias voltages settings changed in production starting at 11572
  • RF prescale factors bad for: 11565-8, 11666-8.

BOR problems

The following production runs have problems with the BOR record, and it is missing from most/all of the files in the run: 10338, 10431, 10493, 10494, 10495, 10496, 10518, 10520, 10563, 10564, 10591, 10593, 10594, 10611, 10612, 10721, 10836 Good runs: 10493, 10494, 10495, 10496, 10518, 10564, 10591, 10594, 10611, 10612


More problem runs: 11144, 11410, 11472

Issues that were calibrated away

  • Sometimes the RF crates shift by 2 ns when rebooted
  • Sometimes the TAGM base times shift by 1 ns
  • Sometimes F1TDC boards shift by ~30 ns (?) at the beginning of a run

One bad file

The only file from approved production runs I couldn't process was Run 11449 File 96

Event #??? (haven't found yet, but near end of file)

Stack trace:

#6  0x0000003fb9689967 in memcpy () from /lib64/libc.so.6
#7  0x0000000000c44ebc in HDEVIO::swap_bank (this=0x7fb3880040e0, outbuff=0x7fb359614670, inbuff=0x7fb388062a00, len=<value optimized out>) at libraries/DAQ/HDEVIO.cc:891
#8  0x0000000000c44ca3 in HDEVIO::swap_bank (this=0x7fb3880040e0, outbuff=0x7fb3595ba010, inbuff=0x7fb3880083a0, len=<value optimized out>) at libraries/DAQ/HDEVIO.cc:912
#9  0x0000000000c47998 in HDEVIO::read (this=0x7fb3880040e0, user_buff=0x7fb3595ba010, user_buff_len=<value optimized out>, allow_swap=true) at libraries/DAQ/HDEVIO.cc:338
#10 0x0000000000c1d1f3 in JEventSource_EVIO::ReadEVIOEvent (this=0x7fb388001090, buff=
0x7fb38d661278) at libraries/DAQ/JEventSource_EVIO.cc:1018
#11 0x0000000000c2a3b5 in JEventSource_EVIO::GetEvent (this=0x7fb388001090, event=...) at libraries/DAQ/JEventSource_EVIO.cc:651
#12 0x0000000000d1dcf3 in jana::JEventSource::GetEvent (this=0x7fb388001090, event=...) at src/JANA/JEventSource.cc:54
#13 0x0000000000cfaa52 in jana::JApplication::ReadEvent (this=0x7fff78e78af0, event=...) at src/JANA/JApplication.cc:742
#14 0x0000000000d04da6 in jana::JApplication::EventBufferThread (this=0x7fff78e78af0) at src/JANA/JApplication.cc:671
#15 0x0000000000d05019 in LaunchEventBufferThread (arg=0x7fff78e78af0) at src/JANA/JApplication.cc:584
#16 0x0000003fb9e079d1 in start_thread () from /lib64/libpthread.so.0
#17 0x0000003fb96e88fd in clone () from /lib64/libc.so.6

Notes

Run Is Good? Notes
10189 x cosmic run, DAQ issues
10190 x 300 A solenoid, DAQ issues
10204 x 1000 A solenoid
10205 x 1000 A solenoid
10206 x DAQ test
10208 x 1000 A solenoid
10209 x solenoid ramping to 1200 A
10210 x solenoid ramping to 1200 A
10212 x solenoid ramping to 1200 A
10216 x solenoid ramping to 1200 A
10230 x MO prescale factors changed during run
10231 x CDC at 2075V
10232 x CDC at 2075V
10234 x CDC at 2100V
10242 x Level 3 trigger off, quad steering test
10244 x DAQ studies with production trigger
10245 x DAQ studies. mode 8?
10247 x DAQ test
10248 x DAQ test
10249 x DAQ test
10251 x DAQ test
10252 x DAQ test
10254 x DAQ test
10257 x first hour long run? yes
10266 x Reset the MO prescale settings, taking a short run 10266.
10267 x no forward tracks (bad FDC readout)
10268 x no forward tracks (bad FDC readout)
10269 x no forward tracks (bad FDC readout)
10270 x no forward tracks (bad FDC readout)
10271 x no forward tracks (bad FDC readout)
10272 x no forward tracks (bad FDC readout)
10273 x DAQ stuck at end of run; restarted; no forward tracks (bad FDC readout)
10275 x no forward tracks (bad FDC readout)
10276 x no forward tracks (bad FDC readout)
10277 x no forward tracks (bad FDC readout)
10278 x no forward tracks (bad FDC readout)
10279 x no forward tracks (bad FDC readout)
10291 x Trigger tests w TPOL converter. Online monitoring test, mode 8? blocking collimator?
10293 x Beam tuning. Working on SC timing (empty target? blocking collimator? no radiator?)
10302 x Empty target (no radiator?) (later logbook entry 8.40am says retracted radiator)
10325 x Empty target run (no radiator?)
10328 x Empty target run (no radiator?)
10330 x Empty target run (no radiator?)
10331 AR ✓ Checklist says 1E-4 radiator
10332 AR ✓ 1e-4 radiator Pi-0 calibration
10338 x Goniometer scan
10339 x DAQ test
10344 x Goniometer scan & DAQ testing
10346 AR ✓ 3E-4 amorphous radiator (FCAL/BCAL physics trigger) shift summary & checklist
10347 diamond radiator
10348
10349
10350
10351
10352 x goniometer studies, very low rate, data quality not great
10354
10356 x started with diamond, low rate/transmission problems? for the first hour, then ~2 more hours with collimator in blocking position (cosmics?)
10366 x incorrect MO scale 3e-4 amorphous radiator 3e-4 (log unclear)
10367 x incorrect MO scale; diamond w poor enhancement
10368 x incorrect MO scale; 3e-4 radiator (blocking collimator? no radiator?)
10369 x incorrect MO scale; 3e-4 radiator
10370 AR ✓ 3e-4 amorphous radiator
10388 x trigger studies mode 8
10389 x trigger studies
10390 diamond!
10391
10392
10394
10395
10396
10399
10400 x FCAL trigger, mode 8 logbook, looks like trigger tests
10403 x FCAL trigger, mode 8 logbook, looks like trigger tests
10411 x no beam/beam tuning
10412 AR ✓ 3e-4 amorphous radiator
10414 DAQ trouble? logbook, monitoring looks okay?
10415
10416
10418
10419 x trigger studies
10420 x trigger studies
10421
10422 x cosmics
10423
10424 AR/x FFB studies + 2E-5 radiator logbook
10431 x mode 8, short run, might be okay? no TOF matching
10434 AR ✓ 3e-4
10435 AR ✓
10436 ragged enhancement logbook
10437
10438
10439
10452 AR/x 3e-4 TAGH HV off
10453 x
10455 x
10456 AR/✓ 3e-4 [doublecheck]
10457 x 8.5 GeV peak [data is fine]
10458 x 7.0 GeV peak [data is fine]
10459 x 7.0 GeV peak [data is fine]
10460 x 7.0 GeV peak [data is fine]
10461 x 6 GeV peak [data is fine]
10462 x 6 GeV peak [data is fine]
10463 x 6 GeV peak [data is fine]
10464 9 GeV peak
10465 9 GeV peak
10491 AR ✓ 3e-4
10492
10493
10494
10495
10496
10497
10498 ended after daq timeout errors
10503 x trigger studies/mode 8 log
10504 x trigger studies/mode 8
10506 x L3 trigger studies
10507 x L3 trigger studies
10518 AR/✓ 3e-4 [doublecheck]
10520 x diamond, mode 8, short run, poor quality
10529 coherent peak 8657 MeV [doublecheck]
10531 AR/x 1e-4 AR, BCAL LED pulsers (short run, no radiator?)
10532 AR/x 1e-4 AR, BCAL LED pulsers
10539 AR/x
10562 AR/✓ [doublecheck]
10563 AR/✓ [doublecheck]
10564 AR/✓ 3e-4 [doublecheck]
10571 x 'not really any good data' log
10572 x 'not really any good data' log
10573 x 'not really any good data' log
10590
10591 AR/✓ log [doublecheck]
10592
10593 mode 8, mostly okay, no FDC recon?
10594 [check data]
10595
10596 x ended after daq timeout errors log
10597
10598
10599 empty target
10601 empty target
10602 empty target
10608 AR/✓ 3e-4 FDC tripped towards end of run log (no radiator?)
10611 [doublecheck]
10612 F1TDC daq errors [doublecheck]
10615
10616 [doublecheck]
10626 x mode 8, trigger study?
10634 AR ✓ 3.4e-4 log
10641 x lots of DAQ problems log
10642 x diamond orientation was changed a few times during these runs
10644 x diamond orientation was changed a few times during these runs
10645 x diamond orientation was changed a few times during these runs
10646
10647 x DAQ trouble & All TOF HV is lower by -100V
10648 All TOF HV is lower by -100V [doublecheck]
10649 x TAGM scan log
10650 x TAGM scan
10651 x TAGM scan
10652 x TAGM scan
10653 x TAGM scan (no radiator?)
10654 x mostly cosmics
10655 x Coherent peak was well below ~9 GeV
10656 ended the run after Timeout Reading F1TDC errs [doublecheck]
10657
10658 x cosmics
10659
10680
10681
10682 x bad quality, look into why?
10685
10686 ended run after F1TDC timeout errors log
10687
10690 x
10691 low quality, not much beam?
10692 x only a minute or two of beam (bad beam?) log
10693
10703 AR ✓ 3e-4 CDC A5 trips (radiator should be 3*10^-4)
10704 Only ~10mins of data before the beam went down.
10707
10720
10721 mode 8, recon problems?
10724
10726 PARA orientation (shows UNKNOWN on the GUI) log [doublecheck]
10727 AR/✓ 3e-4 log [doublecheck]
10729 Stopped Run 10729 after receiving ROCFDC13 F1TDC errors [doublecheck]
10731 [doublecheck]
10733 [doublecheck]
10735 AR/✓ 3e-4,[doublecheck]
10737 check coherent peak 8M events, then ROCTAGM & ROCTAGH stopped responding [doublecheck]
10738 x DAQ crash
10739 check coherent peak ends with ROCTAGH1 crash after 13M events [doublecheck]
10740 x Bad ROCTAGH1
10742 x ROCTAGH1 crashes after a few minutes
10743 check coherent peak ends with ROCTAGH1 crash after 23M events [doublecheck]
10745 x DAQ crashed immediately
10746 check coherent peak [doublecheck]
10748 check coherent peak [doublecheck]
10749 check coherent peak [doublecheck]
10750 check coherent peak [doublecheck]
10752 check coherent peak [doublecheck]
10753 check coherent peak 38 million events before ROCFDC13 crashes [doublecheck]
10755 check coherent peak [doublecheck]
10758 check coherent peak [doublecheck]
10761 x test run
10765 ends with TS crash [doublecheck]
10766 x test run?
10768 ~20 mins of beam [doublecheck]
10777 [doublecheck]
10778 [doublecheck]
10779 AR/✓ 3e-4 [doublecheck]
10780 PARA template reset before this run log [doublecheck]
10781 [doublecheck]
10782 [doublecheck]
10783 [doublecheck]
10784 x L3 testing
10800 x mode 8, trigger test?
10801 x mode 8, trigger test?
10802 x mode 8, trigger test?
10803 x mode 8, trigger test?
10806 x mode 8, trigger test?
10818 x mode 8, trigger test?
10825 x mode 8, trigger test?
10833 [doublecheck]
10834 [doublecheck]
10836 log mode 8 - check this! [doublecheck]
10837 [doublecheck]
10838 TOF HV scan log [doublecheck]
10839 TOF HV scan [doublecheck]
10840 TOF HV scan [doublecheck]
10841 TOF HV scan [doublecheck]
10842 TOF HV scan [doublecheck]
10843 TOF HV scan [doublecheck]
10844 TOF HV scan [doublecheck]
10845 TOF HV scan [doublecheck]
10854 x restarting DAQ
10855 empty target [doublecheck]
10856 x DAQ died after 20secs
10857 empty target [doublecheck]
10858 filled target [doublecheck]log [doublecheck]
10864 x L3 test
10865 x L3 test
10866 x L3 test
10867 Should be a fine production run. [doublecheck]
10871  ?✓ Active target investigations; varied beam current, CDC trips [doublecheck]
10873 [doublecheck]
10875 Ends with DAQ crash [doublecheck]
10876 [doublecheck]
10877 x not writing to raid disks log
10878 x DAQ tests
10879 x DAQ tests
10884 x DAQ tests
10885 x DAQ tests
10893 x DAQ tests
10894  ?✓ 'problem with DAQ still exist' log& log livetime increased w monitoring off [doublecheck]
10895 AR✓ 3e-4 [doublecheck]
10896 x bad diamond
10897 [doublecheck]
10898 x TAGM study
10899 x TAGM study
10900 x TAGM study
10902 x TAGM study
10904 x TAGM study
10905 x TAGM study
10906 [doublecheck]
10907 AR✓ 3e-4 [doublecheck]
10911 [doublecheck]
10912 x bad coherent peak log
10913 [doublecheck]
10914 x trigger studies, mode 8
11040  ???
11041 x mode 8, fix 1x10^-4 radiator
11046 x mode 8, filling?
11047 x mode 8, problems filling target
11048 mode 8, ok
11049 x mode 8, microscope tests
11050 x mode 8, microscope tests
11051 x mode 8, microscope tests
11052 x mode 8, microscope tests
11053 x junk
11054 x mode 8, microscope tests
11055 mode 8
11056 x cosmics
11057 x diamond studies
11058 x short run
11059 20um, PERP
11060 20um, PARA
11061 x short run
11062 x DAQ problems
11063 PERP
11064 20um, PARA
11065 AMO
11067 AMO
11068 AMO
11069 x trigger work
11070 x trigger work
11071 x trigger work
11076 x FCAL test
11078 20um diamond
11082 PARA
11083 x DAQ problems
11084 PERP, DAQ oddness
11085 x DAQ problems
11086 PERP, DAQ oddness
11087 PERP, DAQ oddness
11088 PERP
11089 x uscope test
11090 x uscope test
11091 x uscope test
11092 x uscope test
11093 x uscope test
11094 x uscope test
11095 AMO, 3e-4 RL
11100 PARA
11101 PARA, double check, FFB studies
11103 x short run
11104 PARA
11106 PERP
11107 PERP
11108 PARA
11109 AMO
11112 x trigger studies?
11114 x trigger studies?
11115 x trigger studies?
11117 x trigger studies?
11118 x trigger studies?
11125 x trigger studies?
11127 PARA
11128 PERP
11132 PERP
11136 empty target, PERP
11137 empty target, PARA
11138 PERP
11139 PARA
11140 PARA
11141 PERP
11143 PERP
11144 PERP?
11145 PARA
11147 x collimator scan
11148 x collimator scan
11149 x collimator scan
11150 PARA, check quality
11151 x trigger study
11156 PARA
11157 PERP
11158 PARA
11159 PARA
11160 PERP
11161 PERP
11162 PARA
11164 x trigger study
11166 x trigger study
11183 x TRD study
11184 x TRD study
11185 x TRD study
11186 x short run
11215 x Junk
11216 PARA
11217 PARA
11218 PERP
11219 AMO
11221 x TAGM test
11221 x TAGM test
11223 x TAGM test
11224 x TAGM test
11225 x TAGM test
11226 x TAGM test
11228 x TAGM test
11229 x TAGM test
11230 x TAGM test
11231 x TAGM test
11232 x TAGM test
11233 x TAGM test
11234 x TAGM test
11235 x TAGM test
11236 x TAGM test
11237 x TAGM test
11238 x TAGM test
11239 x 50 um diamond alignment
11243 x PARA, PS field scan ?
11244 x PARA, PS field scan ?
11247 x PS field scan
11248 x PS field scan, mode 8
11249 x PS field scan, mode 8
11250 x PS field scan, mode 8
11258 x PS field scan, mode 8
11259 x PS field scan, mode 8
11260 x Junk
11261 PARA
11262 PERP
11263 PERP
11264 PARA
11265 PERP
11266 PARA
11267 AMO
11269 PARA
11270 PARA
11271 x junk
11272 PARA, trigger holdoff changed, check this
11273 PARA
11275 PERP
11276 PERP
11277 PARA
11295 AMO
11299 x DAQ test
11300 PARA
11301 PERP
11302 PERP
11312 PARA
11347 x quad study
11359 x high luminosity studies
11360 x high luminosity studies
11361 x high luminosity studies
11362 x high luminosity studies
11363 x high luminosity studies
11365 x quad study
11366 PARA
11367 PARA
11368 empty target
11381 AMO, mode 8
11383 AMO, mode 8
11384 AMO
11385 x PARA, quad study
11386 x PARA, quad study
11387 x PARA, quad study
11388 x TAGM study
11389 x TAGM study
11390 x TAGM study
11392 x TAGM study
11393 x TAGM study
11394 x TAGM study
11397 x TAGM study
11400 x TAGM study
11401 x TAGM study
11402 x TAGM study
11403 x TAGM study
11404 PARA
11405 PARA
11406 PERP
11407 PERP
11410 PARA
11411 x PERP, short run, TOF/RF calibration problems
11412 x short
11429 PERP
11430 PERP
11431 PARA
11432 PARA
11433 AMO
11434 AMO
11435 PERP
11436 PARA
11437 PERP
11438 AMO, luminosity studies
11439 x PERP, luminosity studies
11441 x PERP, luminosity studies
11442 x PERP, luminosity studies
11443 x , luminosity studies
11444 x PARA, luminosity studies
11445 PERP
11446 PARA
11447 PERP
11448 PARA
11449 PERP
11450 PARA
11452 PERP
11453 PARA
11454 PERP
11455 AMO
11457 PARA
11458 PERP
11472 PERP
11473 PERP
11474 PARA
11475 AMO
11476 AMO
11477 PERP
11481 PERP
11482 PARA
11483 PERP
11484 PARA
11495 x trigger studies
11497 PARA
11502 x trigger studies
11503 x trigger studies
11504 x trigger studies
11506 x trigger studies
11507 x trigger studies
11508 PERP
11510 PARA
11511 AMO
11512 AMO
11513 PERP
11514 PARA
11519 PARA
11520 PERP
11521 PARA
11529 PERP
11532 PARA
11533 x trigger studies
11539 x trigger studies
11540 x trigger studies
11544 x trigger studies
11545 x trigger studies
11546 x trigger studies
11547 x trigger studies
11550 x trigger studies
11551 x trigger studies
11552 x PARA, integrated TAGH/ST trigger, data might not be good?
11553 PARA
11554 PERP
11555 PERP
11559 x cosmics
11560 x cosmics
11565 x PERP, bad RF prescale
11566 x PARA, bad RF prescale
11568 x AMO, bad RF prescale
11569 PERP
11581 x PARA, bad CDC thresholds
11582 x PARA, bad CDC thresholds
11583 x trigger studies, bad CDC thresholds
11584 x trigger studies
11585 x trigger studies
11586 x trigger studies
11587 x trigger studies
11588 x trigger studies
11589 x trigger studies
11590 x trigger studies
11591 x trigger studies
11592 x trigger studies
11593 x trigger studies
11594 x trigger studies
11595 x trigger studies
11597 PARA
11598 PERP
11599 PARA
11600 PERP
11601 PARA
11602 AMO
11603 PERP
11604 PERP
11605 x junk
11606 x junk
11607 PARA, empty target
11608 x TAGM alignment
11610 x TAGM alignment
11612 x TAGM alignment
11613 x TAGM alignment
11614 x TAGM alignment
11616 PARA, empty target
11617 PARA
11618 PARA
11619 PERP
11620 PARA
11621 PERP
11623 AMO
11625 PARA
11626 PARA
11632 x AMO mode 8, current scan
11633 x AMO mode 8, current scan
11634 x AMO mode 8, current scan
11635 x AMO mode 8, current scan
11636 x AMO mode 8, current scan
11637 x AMO mode 8, current scan
11638 x trigger studies
11639 x trigger studies
11640 x trigger studies
11641 x trigger studies
11642 x PARA, ST-tagger trigger test
11643 x PERP, ST-tagger trigger test
11644 PERP
11645 PERP
11648 PERP
11649 PARA
11650 PERP
11651 AMO
11652 x ST-tagger trigger test
11653 x ST-tagger trigger test
11654 x ST-tagger trigger test
11655 x PERP, ST-tagger trigger test
11656 x PARA, ST-tagger trigger test
11657 PARA
11658 PARA
11659 PERP
11660 x PARA, ST-tagger trigger test
11661 x AMO, ST-tagger trigger test
11662 x AMO, ST-tagger trigger test
11663 PARA
11666 x PARA, bad RF prescale
11667 x PERP, bad RF prescale
11668 x AMO, bad RF prescale


Example of bad BOR run

Run 10492 (Good BOR) Run 10493 (Bad BOR)
Fcal inv mass r10492.png Fcal inv mass r10493.png
Bcal inv mass r10492.png Bcal inv mass r10493.png