FDC Nominal Design Parameters
From GlueXWiki
DRAFT Nominal Design Parameters for FDC ---------------------------------------- Issue for CD-2? Geometry: For each chamber unit Active volume inner radius: 3.5 cm Active volume outer radius: 53.6 cm Chamber assembly outer radius: 65 cm Number of U cathode strips (50 micron Kapton, 5 micron Cu): 192 Number of W cathode strips (50 micron Kapton, 5 micron Cu): 192 Number of sense wires (20 micron gold-plated W): 96 Number of field wires (100 micron gold-plated Al): 97 x Gas (1 cm at 1 at.): Ar/CO2 85/15? Number of cables (34-conductor shielded ribbon cables): 180 Pitch of cathodes: 5 mm? Gap between strips: 1 mm Positioning accuracy of sense wires (x,y): 10 microns? Positioning accuracy of package (z): ? x Number of chamber units per package: 6 x Thickness per package (cm): 12 x Thickness per package (g/cm2): 0.394 x Thickness per package (rad. lengths): 0.012 Thickness of inactive ring: 6.4 cm G10 (10.88 g/cm2) + 1 cm of cable (0.88 g/cm2) per package = 11.76 - 14.40 g/cm2. Location: Package 1 (upstream face):... Package 2 (upstream face): Package 3 (upstream face): Package 4 (upstream face): dE/dX capability: x Cathode strips: NO/YES x Sense wires: NO/YES Operation: Nominal operating voltage (sense):... Nominal operating voltage (field):.... Nominal gas gain: 10^5? Gas flow: five volume change per day? Preamplifier (nominal parameters): Nominal gain: ? Noise level: ? rise time: ? tail compensation: YES Cable length to post-amp: 100 ft? discriminator output: NO/YES? Readout: Cathode strips: 100 MHz FADCs x Sense wires: 8.3 GHz pipeline TDCs Calibration: Cathode strips (selected charge): electronic pulser Sense wires (selected charge): electronic pulser Resolution: Position resolution (sigma_U): 200 microns? Position resolution (sigma_W): 200 microns? Position resolution (sigma_x): 200 microns?