CCDB Tables BCAL

From GlueXWiki
Jump to: navigation, search

Variations

No interesting variations at the moment.


Tables

BCAL/bcal_parms

BCAL_DARKRATE_GHZ 0.0176 Silicon PMT dark rate (from GlueX-doc-1754-v3)
BCAL_SIGMA_SIG_RELATIVE 0.105 Single PE width to amplitude ratio 6.489/61.67 = 0.105 (from GlueX-doc-1754-v3)
BCAL_SIGMA_PED_RELATIVE 0.139 Pedestal width to single PE amplitude ratio 8.585/61.67 = 0.139 (from GlueX-doc-1754-v3)
BCAL_SIPM_GAIN_VARIATION 0.04 Variation of gains between individual SiPM tiles. Yi measured a value of ~4% and indicated this in private communication.
BCAL_XTALK_FRACT 0.10 This factor includes both the cross-talk and after-pulse probability for a 100ns window.
BCAL_INTWINDOW_NS 100. integration widnows in [ns]
BCAL_DEVICEPDE 0.21 Photon detection efficiency (from GlueX-doc-1754-v3)
BCAL_SAMPLING_FRACT 0.095 Sampling Fraction
BCAL_AVG_DARK_DIGI_VALS_PER_EVENT 240 Digitized values due to dark pulses only: Inner region has 3 digitized values/event, Outer region has 2 digitized values/event
BCAL_PHOTONSPERSIDEPERMEV_INFIBER 75 try to extract from GlueX-doc-1069 back to photons per side per MeV in fiber
BCAL_SAMPLINGCOEFA 0.042 Set the sampling smearing coefficients ( from GlueX-doc 827 v3 Figure 13 )
BCAL_SAMPLINGCOEFB 0.013
BCAL_TIMEDIFFCOEFA 0.098994949 time smearing comes from beam test time difference resolution with beam incident on the center of the module
BCAL_TIMEDIFFCOEFB 0 no floor term, but leave the option here
BCAL_THRESH_MEV 1. Threshold applied to energy deposition in MeV (HDGeant)
BCAL_TWO_HIT_RESOL 50. time window for two hit resolution in ns
BCAL_MAX_HITS 100 maximum number of hits per readout channels

BCAL/mc_parms

ATTEN_LENGTH 300.
C_EFFECTIVE 16.75
SiPM_tbin_width 0.100


BCAL/cluster_merging

MIN_CLUSTER_SEPARATION_XY 15.0 Minimum separation between 2 clusters for them NOT to be merged (cm)
MIN_CLUSTER_SEPARATION_Z 30.0

Parameters used for deciding whether 2 BCAL clusters should be merged or not when creating DBCALPhoton objects out of DBCALShower objects