Visual inspection and repairing of lead glass modules

From GlueXWiki
Revision as of 22:40, 17 October 2022 by Somov (Talk | contribs) (Disassemble Lead Glass Module)

Jump to: navigation, search

Disassemble Lead Glass Module


Step 1: Inspect lead glass module (see corresponding section) to make sure the the module has to be disassembled.

Step 2. Loose screws on the flange attached to the PMT housing

Step 3. Remove steel strap assembly holding together the PMT housing and lead glass block

Step 4. Remove silicon cookie (note the cookie may stick to the glass block)