Possible issued with lead glass module

  1. Broken lead glass, see Fig. 1 (module taken from the FCAL prototype)
    • some problems can be seen when looked on the lead glass block from the side opposite to the PMT
    • lead glass module has to be disassembled
  2. Issues with wrapping
    • small damages (holes) of the Aluminized mylar, See Fig. 2. Can be fixed using Al sticky tape, thickness < 20 um
    • Problems with the Al layer in the wrapping foil:
      • Al layer peeled off resulting in some transparent holes in the wrapping.