Test Plan and Setup in Hall A

From GlueXWiki
Revision as of 15:12, 25 August 2010 by Yqiang (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

The Draft Test Plan to Study Radiation Damage to SiPMs in Hall A

System Diagram and Floor Plan

The test setup for SiPM radiation hardness in Hall A during PREX experiment.
The floor plan of the SiPM test in Hall A.


Device List

  • Control Computer: transversity.jlab.org: (129.57.164.28)
  • GPIB over IP: GPIB-ENET/100: agpib.jlab.org (129.57.192.73)
  • Serial Port Server: ESP904: portservha50.jlab.org (129.57.192.78)
  • USB over IP: AnywhereUSB/5: ausb.jlab.org (129.57.192.75)
  • Oscilliscope: TDS3034: dosci.jlab.org (129.57.192.77)
  • Power Outlet: APC Outlet Control: hlauser:hlauser@hareboot12.jlab.org (129.57.192.76)
    • Outlet 1: Pulse Generator
    • Outlet 2: Temperature Box
    • Outlet 3: Oscilliscope
    • Outlet 4: GPIB over IP
    • Outlet 5: Power Supply for Hamamatsu Unit
    • Outlet 6: Power Supply for SensL Unit
    • Outlet 7: Picoamp Meter
    • Outlet 8: Serial Port Server
  • USB to Serial HUB: ComHUB
    • Serial 1 (COM5): Power Supply for Hamamatsu Unit
    • Serial 2 (COM6): Power Supply for SensL Unit
    • Serial 3 (COM7): Oscilliscope
    • Serial 4 (COM8): Temperature Box
  • Picoamp Meter x2: Keithley-485 (GPIB)
    • GPIB Address: 1 (Hamamatsu); 2 (SensL)
  • Pulse Generator: HP-8116A (GPIB)
    • GPIB Address: 4
  • Power Supply x2: B&K-1787B (RS232)
  • Temperature Meter: CN77544 (RS232)

Power Connection and Settings

  • Power Cable Color Code
    • Black: Ground
    • Yellow: -5.0 V
    • Red: +2.1 V
    • Blue: Hamamatsu Bias Voltage
    • Green: SensL Bias Voltage
  • SiPM Bias Voltage Correction vs Temperature
    • Hamamatsu: 56 mV/C (70.27 at 20 C)
    • SensL: 23 mV/C (28.6 at 20 C)

EPICS Variables

Hall A Beam Line IOC: iocha5.jlab.org [129.57.188.5]

  • hac_bcm_average: Hall A beam current (uA)

Hall A Cryo Target IOC: iocha13.jlab.org [129.57.188.29]

  • haBDSPOS.VAL: Hall A cryo target position (encoder value)
List of the encoder readings for the hall A cryo target

MCC general IOC: 129.57.255.4

  • rad44_p2: Neutron dose [mRem/hour]
  • rad44_p2_dose: Accumulated Neutron dose [mRem]
  • rad44_p1: Gamma dose [mRem/hour]
  • rad44_p1_dose: Accumulated Gamma dose [mRem]