Difference between revisions of "Tagger trigger timing"
From GlueXWiki
m |
|||
Line 1: | Line 1: | ||
Below is tagger trigger timing information I got from Eugene Pasyuk. Note that cables are trimmed so the sum of all delays is the same for all T-counters<br><br> | Below is tagger trigger timing information I got from Eugene Pasyuk. Note that cables are trimmed so the sum of all delays is the same for all T-counters<br><br> | ||
− | <table width=" | + | <table width="80%" cellspacing="2" cellpadding="2" border="1"> |
<tr> | <tr> | ||
− | <td valign="top">Delay<br></td> | + | <td valign="top">'''Delay'''<br></td> |
− | <td valign="top">Location<br></td> | + | <td valign="top">'''Location'''<br></td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 43: | Line 43: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td valign="top">50 | + | <td valign="top">50 ns?<br></td> |
− | <td valign="top">cable forward carriage to BCAL | + | <td valign="top">cable forward carriage to BCAL Trigger Supervisor (not installed yet)<br></td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td valign="top">230 + | + | <td valign="top">25 ns? <br></td> |
− | <td valign="top">total delay<br></td> | + | <td valign="top">internal Trigger Supervisor<br></td> |
− | + | </tr> | |
+ | <tr> | ||
+ | <td valign="top">5 ns? <br></td> | ||
+ | <td valign="top">TS to ADC crate<br></td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td valign="top">'''230 + 80 ns?'''<br></td> | ||
+ | <td valign="top">'''total delay'''<br></td> | ||
+ | </tr> | ||
</table> | </table> | ||
<br> | <br> | ||
Note that the photon flight time from the radiator to the BCAL detector is about 100 ns, and that the RadPhi setup has 250 ns delay cables (straight, or 80+170 using a patch panel). | Note that the photon flight time from the radiator to the BCAL detector is about 100 ns, and that the RadPhi setup has 250 ns delay cables (straight, or 80+170 using a patch panel). |
Revision as of 16:56, 14 July 2006
Below is tagger trigger timing information I got from Eugene Pasyuk. Note that cables are trimmed so the sum of all delays is the same for all T-counters
Delay |
Location |
25 ns |
flight time tagger radiator to farthest T-counter |
20 ns |
in T-counter PMT |
50 ns |
cable to CFD |
15 ns |
internal CFD |
5 ns |
cable to L-R coincidence logic module |
5 ns |
internal L-R coincidence logic module |
10 ns |
cable to Master Or module |
20 ns |
internal MOR |
80 ns |
cable MOR to forward carriage |
50 ns? |
cable forward carriage to BCAL Trigger Supervisor (not installed yet) |
25 ns? |
internal Trigger Supervisor |
5 ns? |
TS to ADC crate |
230 + 80 ns? |
total delay |
Note that the photon flight time from the radiator to the BCAL detector is about 100 ns, and that the RadPhi setup has 250 ns delay cables (straight, or 80+170 using a patch panel).