Difference between revisions of "Start Counter Cheat Sheet"

From GlueXWiki
Jump to: navigation, search
(remove mechanical drawing)
Line 5: Line 5:
 
||
 
||
 
[[File:Start_counter.png|thumb|cross-section through barrel, 30-fold segmentation shown]]
 
[[File:Start_counter.png|thumb|cross-section through barrel, 30-fold segmentation shown]]
||
 
[[File:sc_drawing.png|thumb|link=https://halldweb1.jlab.org/wiki/images/2/2a/Sc_drawing.pdf|from mechanical drawing package (PDF)]]
 
 
||
 
||
 
[[File:Sym_30_front_combined.png|thumb|link=https://halldweb1.jlab.org/wiki/images/1/17/Sym_30_front_combined.pdf|SiPM readout concept (PDF)]]
 
[[File:Sym_30_front_combined.png|thumb|link=https://halldweb1.jlab.org/wiki/images/1/17/Sym_30_front_combined.pdf|SiPM readout concept (PDF)]]

Revision as of 20:46, 16 January 2012

3-D rendering of scintillator bars
cross-section through barrel, 30-fold segmentation shown
SiPM readout concept (PDF)
Sym 30 front 2annot.png
  • outer diameter of scattering chamber: 3.72″
    • radius = 4.7244 cm
  • inner diameter of CDC: 6.89″
    • radius = 8.7503 cm
  • scintillator thickness = 3 mm
  • inner surface of scintillator at 73 mm from centerline
    • segmentation of 30
    • scintillator width at inner surface = 15.35 mm
    • scintillator width at outer surface = 15.98 mm
  • plastic package width = 3.85 mm
    • times 4 -> 15.40 mm