Difference between revisions of "Start Counter Cheat Sheet"

From GlueXWiki
Jump to: navigation, search
(SiPM Readout)
 
(24 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{| border
 +
|-
 +
|
 +
[[File:SC 30 overview.png|thumb|3-D rendering of scintillator bars]]
 +
||
 +
[[File:Start_counter.png|thumb|cross-section through barrel, 30-fold segmentation shown]]
 +
||
 +
[[File:Sym_30_front_combined.png|thumb|link=https://halldweb.jlab.org/wiki/images/1/17/Sym_30_front_combined.pdf|SiPM readout concept (PDF)]]
 +
|-
 +
|
 +
[[File:sym_30_front_2annot.png|thumb|link=https://halldweb.jlab.org/wiki/images/1/1f/Sym_30_front_2annot.pdf]]
 +
||
 +
[[File:Start counter chuck.png|thumb|link=https://halldweb.jlab.org/talks/2011-4Q/SC_12_15_11.pptx]]
 +
||
 +
[[File:D00000-01-01-2000.png|thumb|link=https://halldweb.jlab.org/wiki/images/f/fb/D00000-01-01-2000.pdf|mechanical drawing of scintillator (PDF)]]
 +
|}
 
* outer diameter of scattering chamber: 3.72″
 
* outer diameter of scattering chamber: 3.72″
 
** radius = 4.7244 cm
 
** radius = 4.7244 cm
Line 4: Line 20:
 
** radius = 8.7503 cm
 
** radius = 8.7503 cm
 
* scintillator thickness = 3 mm
 
* scintillator thickness = 3 mm
* for a nominal radius of 7.5 cm (roughly that in the Monte Carlo)
+
* inner surface of scintillator at 73 mm from centerline
 
** segmentation of 30
 
** segmentation of 30
*** scintillator width = 15.7 mm
+
** scintillator width at inner surface = 15.35 mm
** segmentation of 40
+
** scintillator width at outer surface = 15.98 mm
*** scintillator width = 11.8 mm
+
* plastic package width = 3.85 mm
 +
** times 4 -> 15.40 mm
  
[[image:Start_counter.png]]
+
[[File:sc_prototype_board.jpg|thumb|read-out board]]
 +
[[File:sc_prototype_cable.jpg|thumb|read-out board with cables]]
 +
 
 +
=Materials=
 +
 
 +
==SiPM Readout==
 +
 
 +
* Hamamatsu S10931-100 MPPC, 3 mm × 3 mm active area, 100 micron pixels
 +
** [[Media:S10362-33 series kapd1023e05.pdf|Spec Sheet]]
 +
** Ordered by A. Somov, [https://www.jlab.org/Hall-D/gluex_secure/procurements/SiPM/PR%20%23%20320603.pdf PR 320603]
 +
*** Note from Sascha on 3/18/21: "we decided to purchase 50 um SiPMs for all sub-detectors"

Latest revision as of 13:35, 22 June 2021

3-D rendering of scintillator bars
cross-section through barrel, 30-fold segmentation shown
SiPM readout concept (PDF)
Sym 30 front 2annot.png
Start counter chuck.png
mechanical drawing of scintillator (PDF)
  • outer diameter of scattering chamber: 3.72″
    • radius = 4.7244 cm
  • inner diameter of CDC: 6.89″
    • radius = 8.7503 cm
  • scintillator thickness = 3 mm
  • inner surface of scintillator at 73 mm from centerline
    • segmentation of 30
    • scintillator width at inner surface = 15.35 mm
    • scintillator width at outer surface = 15.98 mm
  • plastic package width = 3.85 mm
    • times 4 -> 15.40 mm
read-out board
read-out board with cables

Materials

SiPM Readout

  • Hamamatsu S10931-100 MPPC, 3 mm × 3 mm active area, 100 micron pixels
    • Spec Sheet
    • Ordered by A. Somov, PR 320603
      • Note from Sascha on 3/18/21: "we decided to purchase 50 um SiPMs for all sub-detectors"