User contributions
From GlueXWiki
(newest | oldest) View (newer 20 | older 20) (20 | 50 | 100 | 250 | 500)
- 20:57, 30 April 2014 (diff | hist) . . (+3) . . Alarms for voltages (Nerses) (current)
- 20:44, 30 April 2014 (diff | hist) . . (+78) . . Alarms for voltages (Nerses)
- 20:41, 30 April 2014 (diff | hist) . . (0) . . File:Alarm calculation scheme Wiener.jpg (uploaded a new version of "File:Alarm calculation scheme Wiener.jpg": Fixed the Current Alarm Condition block. Marked the area of blocks different from CAEN.) (current)
- 20:40, 30 April 2014 (diff | hist) . . (+2,463) . . Alarms for voltages (Nerses)
- 20:12, 30 April 2014 (diff | hist) . . (0) . . N File:Alarm calculation scheme Wiener.jpg
- 20:12, 30 April 2014 (diff | hist) . . (+45) . . Alarms for voltages (Nerses)
- 09:32, 17 April 2014 (diff | hist) . . (+9) . . Controls Meeting 17-Apr-2014
- 22:16, 16 April 2014 (diff | hist) . . (0) . . File:Alarm calculation scheme.jpg (uploaded a new version of "File:Alarm calculation scheme.jpg": changed the Vfdk to Vfbk) (current)
- 22:13, 16 April 2014 (diff | hist) . . (+2) . . Alarms for voltages (Nerses)
- 22:11, 16 April 2014 (diff | hist) . . (+268) . . Alarms for voltages (Nerses)
- 22:07, 16 April 2014 (diff | hist) . . (-429) . . Alarms for voltages (Nerses)
- 22:05, 16 April 2014 (diff | hist) . . (0) . . File:Alarm calculation scheme.jpg (uploaded a new version of "File:Alarm calculation scheme.jpg": Added the arrow to Compare Alarm block and changed the color to black to indicate NoPassiveProcess (NPP) access.)
- 21:57, 16 April 2014 (diff | hist) . . (0) . . File:Alarm calculation scheme.jpg (uploaded a new version of "File:Alarm calculation scheme.jpg")
- 21:53, 16 April 2014 (diff | hist) . . (+43) . . N File:Alarm calculation scheme.jpg (Alarm calculation scheme for CAEN hardware.)
- 21:50, 16 April 2014 (diff | hist) . . (+56) . . N File:Alarm calculation scheme.pdf (Scheme of alarm calculation for CAEN hardware is drawed.) (current)
- 21:47, 16 April 2014 (diff | hist) . . (+39) . . Alarms for voltages (Nerses)
- 10:00, 3 April 2014 (diff | hist) . . (+148) . . Alarms for voltages (Nerses)
- 09:31, 3 April 2014 (diff | hist) . . (+664) . . N Alarms for voltages (Nerses) (Created page with "For alarms a dedicated MBBI record is implemented with 2 states NO_ALARM and Alarmed. The state itself calculated using CalcOut record. The alarm would be triggered if: If the c...")
- 18:27, 2 April 2014 (diff | hist) . . (+4) . . Controls Meeting 3-Apr-2014
- 09:48, 5 December 2013 (diff | hist) . . (+1) . . Integrated Low/High Voltage system application for Hall-D Detectors (→Configuring and running) (current)