Solenoid Controls Redesign

From GlueXWiki
Revision as of 14:26, 25 October 2011 by Wolin (Talk | contribs)

Jump to: navigation, search

To-do for solenoid controls redesign


  • Recommendations from Director's Review: Electrical System and Quench Protection and Lehman Review
    • determine if cold diodes can increase quench detection
    • add fast DAQ system prior to testing first coil
    • add tests for internal shorts, shorts to ground and ground faults in coil and power supply to start-up sequence
    • add second dump circuit breaker
    • add additional quench circuit diodes
    • add second quench detector (connected to second dump breaker)
    • add center tap to dump resistor and monitor ground current in the PLC
    • add UPS on dump breakers to avoid fast discharges
    • perform Failure Modes and Effects Analysis (FMEA)


  • Infrastructure
    • get fourth rack, install temporary wheels, bolt to other three racks, install computer and other equipment


  • Cryo system
    • need specs, new channels, new functionality, etc. from Jonathan


  • Wiring
    • document trip chains
    • label circuit breakers
    • use Sequence-Of-Events (SOE) module, need additional wiring and relays
      • prototype use of SOE module and relays in controls test stand
    • improve voltage range and eliminate cross-talk on voltage tap channels
      • change connection scheme?
      • change current limiting scheme?
      • requirements: fast vs slow, high vs low voltage, high vs low precision
      • Cody will look into this


  • Danfysik power supply
    • use 435NBX to talk to power supply
    • choose ground fault detection mechanism
    • lockbox for door key
    • lock/tag/try procedures for dump resistor
    • procedures to check for dump resistor integrity and diode polarity prior to startup


  • Quench detector
    • can we get a good balance...need sub-coil inductances from Floyd (Fall 2011)
    • do we need a second QD? second technology? do we eed to design our own?
    • can we get an FPGA module with A/D inputs off the shelf to do this?


  • Instrumentation
    • implement system to isolate fault detectors and determine time sequence of trips
    • implement RS232 connections to all devices (e.g. vacuum gauges)
    • Use RTI 435NBX instead of Point I/O serial modules
    • Replace shunt with flux-monitoring sensor


  • VME-based fast DAQ
    • NI vs VME?
    • connection to PLC?
    • connection to EPICS?


  • A-B HMI improvements
    • fault sequence screens
    • Viewpoint
      • get screens on the web
      • security?


    • EWEB
      • create tag lists
      • security?


  • A-B PLC programming
    • consider existing program a prototype, rework for 15-20 year lifetime
    • send Josh to A-B training?
    • custom ("add-on") instructions to simplify everything
    • use function block, structured text and ladder logic as appropriate


  • EPICS
    • new channels


  • UPS power
    • solenoid controls racks
    • Danfysik control circuits and contactor?
    • target? other cryo and vacuum systems?
    • cooling systems (dewpoint)?
    • downtime due to power loss is deciding factor



Notes

  • max ramp rate in the hall is approximately 10V / 20H = 0.5 A/sec


Possible future improvements

  • monitor selected circuit breakers so operators can quickly find them when they trip