  rdesktop halld2 -g 1800x1000
 
  rdesktop halld2 -g 1800x1000
 
2. Double click the shortcut '''Field_Logger''' on the desktop to run the LabVIEW application
 
2. Double click the shortcut '''Field_Logger''' on the desktop to run the LabVIEW application
 
+
# Verify all readings are updating
 +
# Choose type of file operation (default: open or create)
 +
# Open or Create a data file
 +
# Load the appropriate Z preset file
 +
# Use '''Previous''' and '''Next''' to choose the starting Z position if needed
 +
# Move and turn the probes to desired Z position with a very small incline angle (both readings should be in green)
 +
# Click '''Record''' to record current readings
 +
# Continue to next point
  
 
==Files ==
 
==Files ==

Revision as of 19:33, 19 June 2013

Field Mapping System Diagram

Field Mapping.png

Running the Field Logger Software

1. Use remote desktop to log onto halld2 using account 'JLAB\halldusers', ask Elliott for password

rdesktop halld2 -g 1800x1000

2. Double click the shortcut Field_Logger on the desktop to run the LabVIEW application

  1. Verify all readings are updating
  2. Choose type of file operation (default: open or create)
  3. Open or Create a data file
  4. Load the appropriate Z preset file
  5. Use Previous and Next to choose the starting Z position if needed
  6. Move and turn the probes to desired Z position with a very small incline angle (both readings should be in green)
  7. Click Record to record current readings
  8. Continue to next point

Files

The files are stored on the halld-online group disk here:

/group/halld-online/Solenoid_Mapping

Which should also be accessible from the "M:" drive

The file names are formatted to contain the date, start time, phi value, and radius. For example, the following file was:

  • created on May 1st, 2013 at 11:39am
  • the strut was positioned such that the tube positions were along φ=90o
  • tube was at R=0 (i.e. along the center of the magnet).
Field_Data_20130501_1139_P90_R12.dat

The columns of a data file are: radius(inch), phi(deg), Z(cm), Incline(deg), B_x(Gauss), B_y(Gauss), B_z(Gauss) and B_axial(Gauss). And the X,Y,Z direction are defined as

  • X: points to the beam left
  • Y: points vertically up
  • Z: points to the beam dump