The periods in BOLD are calibrated i.e. have a pedestal and gain tables. Each period corresponds to an arbitrary 24h block from 00:00 to 00:00+24:00. These periods do not match yet the the FCAL hardware changes. The run ranges of the FCAL hardware changes are currently in the process to be determined.
 
The periods in BOLD are calibrated i.e. have a pedestal and gain tables. Each period corresponds to an arbitrary 24h block from 00:00 to 00:00+24:00. These periods do not match yet the the FCAL hardware changes. The run ranges of the FCAL hardware changes are currently in the process to be determined.
  
#Periods
+
== Periods ==
 
#* D, 7 days or periods
 
#* D, 7 days or periods
 
#**period 1 / run range: 90207-90208 / number of runs:2
 
#**period 1 / run range: 90207-90208 / number of runs:2
Line 48: Line 48:
 
#**period 19 / run range: 90515-90526 / number of runs:12
 
#**period 19 / run range: 90515-90526 / number of runs:12
 
#**'''period 20 / run range: 90527-90536 / number of runs:10'''
 
#**'''period 20 / run range: 90527-90536 / number of runs:10'''
#Gain matching calibration plots
+
== Gain matching calibration plots ==
 
#* [https://halldweb.jlab.org/primexd/src-he/ He QC/QA]
 
#* [https://halldweb.jlab.org/primexd/src-he/ He QC/QA]
 
#* [https://halldweb.jlab.org/primexd/d_src/ d QC/QA]
 
#* [https://halldweb.jlab.org/primexd/d_src/ d QC/QA]
 
#* [https://halldweb.jlab.org/primexd/c_src/ C QC/QA]
 
#* [https://halldweb.jlab.org/primexd/c_src/ C QC/QA]
 
# [[ Checking the FCAL gains ]]
 
# [[ Checking the FCAL gains ]]
# Energy dependence correction monitoring plots
+
== Energy dependence correction monitoring plots ==

Revision as of 12:30, 19 January 2022

The periods in BOLD are calibrated i.e. have a pedestal and gain tables. Each period corresponds to an arbitrary 24h block from 00:00 to 00:00+24:00. These periods do not match yet the the FCAL hardware changes. The run ranges of the FCAL hardware changes are currently in the process to be determined.

Periods

    • D, 7 days or periods
      • period 1 / run range: 90207-90208 / number of runs:2
      • period 2 / run range: 90209-90225 / number of runs:15
      • period 3 / run range: 90226-90241 / number of runs:11
      • period 4 / run range: 90242-90249 / number of runs:8
      • period 5 / run range: 90558-90571 / number of runs:13
      • period 6 / run range: 90572-90589 / number of runs:18
      • period 7 / run range: 90590-90601 / number of runs:12
    • He, 17 days or periods
      • period 1 / run range: 90034-90035 / number of runs:2
      • period 2 / run range: 90036-90059 / number of runs:7
      • period 3 / run range: 90061-90073 / number of runs:8
      • period 4 / run range: 90074-90087 / number of runs:13
      • period 5 / run range: 90088-90103 / number of runs:13
      • period 6 / run range: 90104-90120 / number of runs:12
      • period 7 / run range: 90121-90132 / number of runs:12
      • period 8 / run range: 90133-90145 / number of runs:12
      • period 9 / run range: 90146-90161 / number of runs:15
      • period 10 / run range: 90162-90168 / number of runs:7
      • period 11 / run range: 90169-90182 / number of runs:12
      • period 12 / run range: 90183-90193 / number of runs:9
      • period 13 / run range: 90194-90200 / number of runs:5
      • period 14 / run range: 90607-90623 / number of runs:15
      • period 15 / run range: 90624-90647 / number of runs:12
      • period 16 / run range: 90653-90658 / number of runs:6
      • period 17 / run range: 90660-90660 / number of runs:2
    • C, 19 days or periods
      • period 2 / run range: 90263-90276 / number of runs:12
      • period 3 / run range: 90277-90292 / number of runs:15
      • period 4 / run range: 90293-90305 / number of runs:13
      • period 5 / run range: 90306-90318 / number of runs:13
      • period 6 / run range: 90319-90332 / number of runs:14
      • period 7 / run range: 90333-90347 / number of runs:14
      • period 8 / run range: 90348-90354 / number of runs:5
      • period 9 / run range: 90355-90367 / number of runs:12
      • period 10 / run range: 90368-90383 / number of runs:14
      • period 11 / run range: 90384-90402 / number of runs:12
      • period 12 / run range: 90403-90416 / number of runs:12
      • period 13 / run range: 90417-90432 / number of runs:14
      • period 14 / run range: 90433-90447 / number of runs:13
      • period 15 / run range: 90448-90458 / number of runs:7
      • period 16 / run range: 90469-90481 / number of runs:11
      • period 17 / run range: 90482-90497 / number of runs:13
      • period 18 / run range: 90498-90514 / number of runs:9
      • period 19 / run range: 90515-90526 / number of runs:12
      • period 20 / run range: 90527-90536 / number of runs:10

Gain matching calibration plots

  1. Checking the FCAL gains

Energy dependence correction monitoring plots