Line 55: Line 55:
 
| CDC || TBD || TBD || TBD
 
| CDC || TBD || TBD || TBD
 
|-  
 
|-  
| TAGH || channel 1-16 has two peaks of hits || all runs || TBD
+
| TAGH || channel 1-16 has two peaks in TDC-ADC plots || all runs || TBD
 +
|-
 +
| TAGH || channel 104 has two peaks in TDC-ADC plots || 90117-90453 || TBD
 +
|-
 +
| TAGH || channel 179-185 behaves abnormal due to bad FADC || 90428-90453 || TBD
 
|-  
 
|-  
 
| TAGM || channel 100 has very low occupancy || all runs || TBD
 
| TAGM || channel 100 has very low occupancy || all runs || TBD
 
|}
 
|}

Revision as of 14:06, 2 August 2022

Overview of subdetectors

Detector Tasks Calibration expert
CDC gains, dE/dx, time-to-distance Simon Taylor
FDC timing, wire plane, pedestals, gain/energy non-linearities Keigo Mizutani
BCAL timing, z-position, gain ratios, gains, non-linearities Mark Dalton, Karthik Suresh
FCAL gains/non-linearities/timing Igal Jaegle
TOF timing offsets, timewalk, attenuation, gain Beni Zihlmann
ST timing, resolution Sean Dobbs
TAGH timing offsets, timewalk Alex Somov
TAGM timing offsets, timewalk Alex Somov
PS timing offsets, timewalk Alex Somov

Monitoring launches

Version Date Files per run Compared with last version
00 during each run a few percent of all data created online by RootSpy
01 shortly after each run 5 first launch
02 01/07/2022 40 various calibration updates
03 02/14/2022 5 various calibration updates
04 03/14/2022 5 various calibration updates
05 04/22/2022 40 (90271-90378), 5 (rest) various calibration updates
06 07/03/2022 2 BCAL calibrations added, photon beam endpoint energy added
07 07/27/2022 2 Photon beam endpoint energy corrected, TAGH calibrations of Compton runs added
  • Calibration check spreadsheets:
  • Location of output files:
    • Monitoring histograms, REST files, standalone files specific to some sub-detectors (one per EVIO file): /mss/halld/offline_monitoring/RunPeriod-2021-11/verXX
    • Merged histogram files (one per run): /work/halld/data_monitoring/RunPeriod-2021-11/mon_verXX/rootfiles/

Data quality issues

  • Some hardware or software issues can not be fixed by calibrations. Attention is needed during the data analysis
Subdetector Issue Runs affected Actions required
CDC TBD TBD TBD
TAGH channel 1-16 has two peaks in TDC-ADC plots all runs TBD
TAGH channel 104 has two peaks in TDC-ADC plots 90117-90453 TBD
TAGH channel 179-185 behaves abnormal due to bad FADC 90428-90453 TBD
TAGM channel 100 has very low occupancy all runs TBD