Difference between revisions of "SRC/CT Detector Calibration"

From GlueXWiki
Jump to: navigation, search
Line 27: Line 27:
 
! Version !! Date  !! Files per run !! Compared with last version
 
! Version !! Date  !! Files per run !! Compared with last version
 
|-  
 
|-  
| 01 || TBA || TBA || TBA
+
| 00 || online monitoring || a few percent of all data || TBA
 
|-  
 
|-  
| 02 || TBA || TBA || TBA  
+
| 01 || shortly after each run || 5 || TBA
 +
|-
 +
| 02 || 01/07/2022 || 40 || TBA  
 
|-
 
|-
| 03 || TBA || TBA || TBA
+
| 03 || 02/14/2022 || 5 || TBA
 
|-
 
|-
| 04 || TBA || TBA || TBA
+
| 04 || 03/14/2022 || 5 || TBA
 
|-  
 
|-  
| 05 || TBA || TBA || TBA
+
| 05 || 04/22/2022 || 40 (90271-90378), 5 (rest) ||
 
|-  
 
|-  
 
| 06 || 07/03/2022 || 2 || BCAL calibrations added, photon beam endpoint energy added
 
| 06 || 07/03/2022 || 2 || BCAL calibrations added, photon beam endpoint energy added
Line 43: Line 45:
 
*Calibration check spreadsheets:
 
*Calibration check spreadsheets:
 
*Location of output files:
 
*Location of output files:
 +
**monitoring histograms, REST files, standalone files specific to some sub-detectors: /cache/halld/offline_monitoring/RunPeriod-2021-11/verXX
 +
**merged histogram files: /work/halld/data_monitoring/RunPeriod-2021-11/mon_verXX/rootfiles/
  
  

Revision as of 10:39, 2 August 2022

Overview of subdetectors

Detector Tasks Calibration expert
CDC gains, dE/dx, time-to-distance Simon Taylor
FDC timing, wire plane, pedestals, gain/energy non-linearities Keigo Mizutani
BCAL timing, z-position, gain ratios, gains, non-linearities Mark Dalton, Karthik Suresh
FCAL gains/non-linearities/timing Igal Jaegle
TOF timing offsets, timewalk, attenuation, gain Beni Zihlmann
ST timing, resolution Sean Dobbs
TAGH timing offsets, timewalk Alex Somov
TAGM timing offsets, timewalk Alex Somov
PS timing offsets, timewalk Alex Somov

Monitoring launches

Version Date Files per run Compared with last version
00 online monitoring a few percent of all data TBA
01 shortly after each run 5 TBA
02 01/07/2022 40 TBA
03 02/14/2022 5 TBA
04 03/14/2022 5 TBA
05 04/22/2022 40 (90271-90378), 5 (rest)
06 07/03/2022 2 BCAL calibrations added, photon beam endpoint energy added
07 07/27/2022 2 Photon beam endpoint energy corrected, TAGH calibrations of Compton runs added
  • Calibration check spreadsheets:
  • Location of output files:
    • monitoring histograms, REST files, standalone files specific to some sub-detectors: /cache/halld/offline_monitoring/RunPeriod-2021-11/verXX
    • merged histogram files: /work/halld/data_monitoring/RunPeriod-2021-11/mon_verXX/rootfiles/


Data quality issues

  • Some hardware or software issues can not be fixed by calibrations. Attention is needed during the data analysis
Subdetector Issue Runs affected Actions required
CDC TBA TBA TBA
TAGH channel 1-16 has two peaks of hits all runs TBD
TAGM channel 100 has very low occupancy all runs TBD