Difference between revisions of "Run Planning Meeting Notes, Mar 1-Mar 7, 2018"
From GlueXWiki
(→Thursday, March 1) |
(→Thursday, March 1) |
||
Line 12: | Line 12: | ||
#* For these runs: (i) Hovanes reverted the collimator position to the same value used in the previous current scan, (ii) We reverted to the previous value of the CDC window offset | #* For these runs: (i) Hovanes reverted the collimator position to the same value used in the previous current scan, (ii) We reverted to the previous value of the CDC window offset | ||
# Issues: | # Issues: | ||
− | #* (fixed) Sean updated the CDC timing for the low intensity scan, see [https://logbooks.jlab.org/entry/3540445]. This has to be switched it back in production (see also this [https://logbooks.jlab.org/entry/3537413 entry]). | + | #* (fixed) Sean updated the CDC timing for the low intensity scan, see [https://logbooks.jlab.org/entry/3540445]. This has to be switched it back in production (see also this [https://logbooks.jlab.org/entry/3537413 entry]). How to restore production running (by Elton) [https://logbooks.jlab.org/entry/3540466]. |
# Reports (some of these shown at the AWG yesterday): | # Reports (some of these shown at the AWG yesterday): | ||
− | #* Production vertex position [https://logbooks.jlab.org/entry/3540250 before/after collimator shift] | + | #* Production vertex position [https://logbooks.jlab.org/entry/3540250 before/after collimator shift] (runs 40496 and 40509) [AA] |
+ | #* Pedestals Monitor FCAL, BCAL (run 41546 - production) [https://logbooks.jlab.org/entry/3540258] [SF] | ||
# Planning: | # Planning: | ||
#* updated run time chart [https://halldweb1.jlab.org/wiki/index.php/File:Spring18_week8.jpg] | #* updated run time chart [https://halldweb1.jlab.org/wiki/index.php/File:Spring18_week8.jpg] |
Revision as of 00:28, 1 March 2018
<- Back to Run Coordination Meetings:Fall2017 Spring2018 Run
Thursday, March 1
- Notes from the previous 24 hours:
- Production Data with 58um JD70-100 diamond in the early afternoon
- At about 6pm, we started low intensity scan see Justin's google sheet
- For these runs: (i) Hovanes reverted the collimator position to the same value used in the previous current scan, (ii) We reverted to the previous value of the CDC window offset
- Issues:
- Reports (some of these shown at the AWG yesterday):
- Production vertex position before/after collimator shift (runs 40496 and 40509) [AA]
- Pedestals Monitor FCAL, BCAL (run 41546 - production) [3] [SF]
- Planning:
- updated run time chart [4]
- Today's run plan Run Plan Google Calendar Accel. Run Plan Google Calendar:
- Harp scan in early morning: ... [enter log entry here]
- ... add itemized list of actions taken