== Past 24 hours ==
 +
* no beam during the day, machine optimization to deliver high current beam to HallC (unsuccessful)
 +
* beam back around 5:30pm
 +
* did first two Harp scans with HallD laser on and off while hallC had around 17uA of beam
 +
** [https://logbooks.jlab.org/entry/4008902 Scan One with our beam]
 +
** [https://logbooks.jlab.org/entry/4008909 Scan Two only HallC beam]
 +
** [https://logbooks.jlab.org/entry/4008895 Scan results at collimator]
 +
** peak to base line of the harp peaks is about 100 (as in previous scans)
 +
* general beam conditions are rather unstable. [https://logbooks.jlab.org/entry/4008917 beam strip chart]
 +
* continue data taking over night
 +
* DAQ issues again with life time dropping to 60%. Shift crew called Sergey.
 +
** found problem with Slot 3 fiber 7 having trouble (I think this is seen in roctrig1?)
 +
** after Sergey's intervention DAQ came slowly back to "normal"
 +
* beam conditions are very unstable over night
 +
* [https://logbooks.jlab.org/entry/4009005 Loss of NMR comm in Tagger Manet ]
 +
* again very bad life time 10% only! but also beam lost around 4am
 +
* beam on and off for some time, finally off with problems in several, cavity one whole zone no beam for several hours.

Revision as of 06:27, 30 June 2022

Back to Run Coordination Meetings:Summer2022

Meeting are via ZoomGov: connect (Meeting ID: 160 199 0060 / Passcode 8394)

MCC whiteboard

Hall D counting room white board

Spreadsheet with list of runs

Thursday June 30

Past 24 hours

  • no beam during the day, machine optimization to deliver high current beam to HallC (unsuccessful)
  • beam back around 5:30pm
  • did first two Harp scans with HallD laser on and off while hallC had around 17uA of beam
  • general beam conditions are rather unstable. beam strip chart
  • continue data taking over night
  • DAQ issues again with life time dropping to 60%. Shift crew called Sergey.
    • found problem with Slot 3 fiber 7 having trouble (I think this is seen in roctrig1?)
    • after Sergey's intervention DAQ came slowly back to "normal"
  • beam conditions are very unstable over night
  • Loss of NMR comm in Tagger Manet
  • again very bad life time 10% only! but also beam lost around 4am
  • beam on and off for some time, finally off with problems in several, cavity one whole zone no beam for several hours.