Difference between revisions of "RunPeriod-2022-08 Validation"

From GlueXWiki
Jump to: navigation, search
(Monitoring Status)
Line 109: Line 109:
 
* Problematic TAGM channel: 64
 
* Problematic TAGM channel: 64
 
* These runs should have been marked as solenoid off, but were not - this is fixed now - 110469-110482, 110600-110621, 111969-112001
 
* These runs should have been marked as solenoid off, but were not - this is fixed now - 110469-110482, 110600-110621, 111969-112001
 +
 +
 +
 +
= Production checklist =
 +
 +
* Check RF monitoring plots
 +
* Check other monitoring histos - done
 +
* Recalibrations - waiting for SC, then new launch, then CDC, BCAL
 +
* Geometry - waiting for sdmes
 +
* Final monitoring launch to check recalibrations

Revision as of 10:01, 21 March 2024


Run List


Monitoring Launch Checks

Team members

  • BCAL: Zisis Papandreou/Regina + Tolga Erbora
  • CCAL: Drew Smith
  • CDC: Alison Laduke
  • FCAL: Susan Schadmand
  • FDC: Dene Hoffman
  • PS/PSC: Susan Schadmand
  • SC: Viviana Arroyave
  • TAGH/TAGM: Saheli Rakshit
  • TOF: Jesse Hernandez
  • Timing: Nizar Septian
  • Analysis: Zach Baldwin


Detector/Calibration Experts

  • BCAL: Mark Dalton, Zisis Papandreou, Igal Jaegle
  • CCAL: Drew Smith
  • CDC: Naomi Jarvis
  • FCAL: Mark Dalton, Malte Albrecht, Igal Jaegle
  • FDC: Lubomir Pentchev
  • PS/PSC: Alex Somov, Olga Cortes
  • SC: Beni Zihlmann
  • TAGH: Alex Somov, Bo Yu
  • TAGM: Richard Jones, Ellie Prather
  • TOF: Paul Eugenio, Beni Zihlmann
  • Timing: Sean Dobbs
  • Analysis: Igal Jaegle


Monitoring Status

Detector Monitoring Expert checks
BCAL in progress pending
CCAL done done
CDC done done
FCAL Timing, Occupancy, and pi0 Peak: done pending
FDC done pending
PS/PSC Timing, Occupancy, and PS pair energy: done pending
SC done pending
TAGH/TAGM done pending
TOF done pending
Timing done done
Analysis DONE pending

Data monitoring

Notes

  • 110675 low CDC efficiency - fine in v12
  • 110695 low CDC efficiency (no plot) - fine in v12
  • 110790 low CDC efficiency - fine in v12
  • 111269 low CDC efficiency - fine in v12
  • 111664 low CDC efficiency - fine in v12

Problem runs

ver13 monitoring launch

  • Runs to ignore: 110469, 110485, 110486 - marked as bad
  • Run 111771 - looks like SC electronics weren't correctly initialized - marked as bad
  • This is a weird one (two) on the latest monitoring - 111404, 111405 - calibrations mostly seem okay, but the rate of good events is low. I think that the rate is thrown off by the bad FCAL fADC - could consider just tossing this run.
    • 111694 also seems driven by a noisy fADC
    • all three marked as bad
  • Problematic TAGM channel: 64
  • These runs should have been marked as solenoid off, but were not - this is fixed now - 110469-110482, 110600-110621, 111969-112001


Production checklist

  • Check RF monitoring plots
  • Check other monitoring histos - done
  • Recalibrations - waiting for SC, then new launch, then CDC, BCAL
  • Geometry - waiting for sdmes
  • Final monitoring launch to check recalibrations