Difference between revisions of "Resolutions"

From GlueXWiki
Jump to: navigation, search
m (Resolutions)
m (Resolutions)
Line 44: Line 44:
 
** diffusion
 
** diffusion
  
 +
 +
* Table with resolutions for straw 7 and different clock settings:
 +
** high: with hit removed from tracking
 +
** low: with hit included
 
{| border="1"  
 
{| border="1"  
 
|-
 
|-

Revision as of 13:57, 10 July 2009

Prelude

  • Two gases are used: 70/30 and 90/10 Ar/CO2
  • Two fADC clock settings are used: 125 and 200 MHz
  • Drift time spectra (DCOG method is used):
90/10 Ar/CO2 drift time spectra.
70/30 Ar/CO2 drift time spectra.
  • Red line is fit to get absolute minimal drift time
    • Best tracking results if extracted minimal drift time + 1 time sample
  • Samples per rising edge - 2 extra samples 125 -> 200 MHz
Samples/rising edge - 70/30 Ar/CO2 - 125~MHz clock.
Samples/rising edge - 70/30 Ar/CO2 - 200~MHz clock.
  • Time-2-distance relation:
    • GARFIELD is used. To get best resolutions out of it:
      • 68/32 Ar/CO2 is put in GARFIELD for 70/30 gas
      • 89/11 Ar/CO2 is put in GARFIELD for 90/10 gas
      • +-6% CO2 can give 100~ns difference


Resolutions

  • Difference in gases - blue line is a model prediction:
Resolutions (in um) as a function of distance to the wire (in mm) for 70/30.
Resolutions (in um) as a function of distance to the wire (in mm) for 90/10.
  • 90/10 worse because shorter drift times.
  • Model contains:
    • Timing resolution
    • accuracy
    • diffusion


  • Table with resolutions for straw 7 and different clock settings:
    • high: with hit removed from tracking
    • low: with hit included
Distance from wire [mm] Resolution (low) [um] Resolution (high [um]
125 MHz 200 MHz 125 MHz 200 MHz
0-1 388 394 404 396
1-2 346 292 346 205
2-3 209 191 222 210
3-4 142 135 166 165
4-5 118 96 164 151
5-6 85 88 148 164
6-7 67 70 165 174
7-8 65 63 158 169