Difference between revisions of "Resolutions"

From GlueXWiki
Jump to: navigation, search
m
m
Line 1: Line 1:
 +
= Prelude =
 
* Two gases are used: 70/30 and 90/10 Ar/CO2
 
* Two gases are used: 70/30 and 90/10 Ar/CO2
 
* Two fADC clock settings are used: 125 and 200 MHz
 
* Two fADC clock settings are used: 125 and 200 MHz
Line 20: Line 21:
 
|-
 
|-
 
|}
 
|}
 +
 +
* Time-2-distance relation:
 +
** GARFIELD is used. To get best resolutions out of it:
 +
*** 68/32 Ar/CO2 is put in GARFIELD for 70/30 gas
 +
*** 89/11 Ar/CO2 is put in GARFIELD for 90/10 gas

Revision as of 11:48, 10 July 2009

Prelude

  • Two gases are used: 70/30 and 90/10 Ar/CO2
  • Two fADC clock settings are used: 125 and 200 MHz
  • Drift time spectra (DCOG method is used):
90/10 Ar/CO2 drift time spectra.
70/30 Ar/CO2 drift time spectra.
  • Red line is fit to get absolute minimal drift time
    • Best tracking results if extracted minimal drift time + 1 time sample
  • Samples per rising edge - 2 extra samples 125 -> 200 MHz
Samples/rising edge - 70/30 Ar/CO2 - 125~MHz clock.
Samples/rising edge - 70/30 Ar/CO2 - 200~MHz clock.
  • Time-2-distance relation:
    • GARFIELD is used. To get best resolutions out of it:
      • 68/32 Ar/CO2 is put in GARFIELD for 70/30 gas
      • 89/11 Ar/CO2 is put in GARFIELD for 90/10 gas