Difference between revisions of "Preamp 4: Comparison of cosmic data with original preamp"
From GlueXWiki
Line 1: | Line 1: | ||
− | The pictures below show ADC amplitude histograms for cosmic ray data with 50/50 Ar/CO2 gas mixture | + | The pictures below show ADC amplitude histograms for cosmic ray data with 50/50 Ar/CO2 gas mixture (the maximum ADC amplitude for each event contributes one entry for that amplitude in the histogram). |
+ | |||
+ | <br> | ||
+ | |||
+ | These compare data taken using the old and new preamps - the "old" preamp is the original one and the "new" preamp is Preamp4, described in Table 2 row 2 of GlueX-doc-1364 and labelled 27. | ||
<br> | <br> |
Revision as of 09:43, 9 June 2010
The pictures below show ADC amplitude histograms for cosmic ray data with 50/50 Ar/CO2 gas mixture (the maximum ADC amplitude for each event contributes one entry for that amplitude in the histogram).
These compare data taken using the old and new preamps - the "old" preamp is the original one and the "new" preamp is Preamp4, described in Table 2 row 2 of GlueX-doc-1364 and labelled 27.
2050V
2100V - the new preamp is saturating at this voltage