Difference between revisions of "Preamp 4: Comparison of cosmic data with original preamp"

From GlueXWiki
Jump to: navigation, search
Line 9: Line 9:
 
|}
 
|}
  
2100V
+
2100V - the new preamp is saturating at this voltage
 
{| border="1" cellpadding="2"
 
{| border="1" cellpadding="2"
 
|width="415pt"|[[Image:cosmic_amplitude_2100V_old_preamp.jpg|thumb|none|400px|old preamp, cosmics, 50/50 Ar/CO2, 2100V]]
 
|width="415pt"|[[Image:cosmic_amplitude_2100V_old_preamp.jpg|thumb|none|400px|old preamp, cosmics, 50/50 Ar/CO2, 2100V]]
 
|width="415pt"|[[Image:cosmic_amplitude_2100V_preamp4.jpg|thumb|none|400px|new preamp, cosmics, 50/50 Ar/CO2, 2100V]]
 
|width="415pt"|[[Image:cosmic_amplitude_2100V_preamp4.jpg|thumb|none|400px|new preamp, cosmics, 50/50 Ar/CO2, 2100V]]
 
|}
 
|}

Revision as of 09:39, 9 June 2010

The pictures below show ADC amplitude histograms for cosmic ray data with 50/50 Ar/CO2 gas mixture. The maximum ADC amplitude for each event contributes one entry (at that amplitude) in the histogram. These compare data taken using the old and new preamps - the "old" preamp is the original one and the "new" preamp is Preamp4, described in Table 2 row 2 of GlueX-doc-1364 and labelled 27.


2050V

old preamp, cosmics, 50/50 Ar/CO2, 2050V
new preamp, cosmics, 50/50 Ar/CO2, 2050V

2100V - the new preamp is saturating at this voltage

old preamp, cosmics, 50/50 Ar/CO2, 2100V
new preamp, cosmics, 50/50 Ar/CO2, 2100V