Difference between revisions of "Pair Spectrometer Magnet Simulation"

From GlueXWiki
Jump to: navigation, search
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
[[Image:primex.png|thumb|left Primex ]]
+
#18D36 magnet simulation with TOSCA
 +
[[Image:primex.png|thumb|left|420px|alt=Primex magnet Simulation, 8 inch gap size ]]
 +
[[Image:hall_d.png|thumb|420px| Hall-D, 3 inch gap size  ]]
 +
# Operation current density:
 +
#*  PRIMEX 8.08"(20.54cm)gap:  564A/cm2=13500.Gauss
 +
#*  3" gap:                    527.5A/cm2=22950.Gauss  (413 A/cm2 = 1.8 T, linearity has to be checked)
 +
# TOSCA installed in the Hall-D group
 +
  /group/halld/Software/tosca/
 +
#Field map (implementing to Hall-D Geant Simulation)
 +
#* X:  0 - 24cm, 2 cm bin size  (12 bins)
 +
#* Y:  0 - 3.81 cm, 0.762 cm bin size (5 bins)
 +
#* Z:  0 - 150 cm, 2.5 cm bin size (60 bins)

Latest revision as of 10:09, 7 March 2011

  1. 18D36 magnet simulation with TOSCA
Primex magnet Simulation, 8 inch gap size
Hall-D, 3 inch gap size
  1. Operation current density:
    • PRIMEX 8.08"(20.54cm)gap: 564A/cm2=13500.Gauss
    • 3" gap: 527.5A/cm2=22950.Gauss (413 A/cm2 = 1.8 T, linearity has to be checked)
  2. TOSCA installed in the Hall-D group
  /group/halld/Software/tosca/
  1. Field map (implementing to Hall-D Geant Simulation)
    • X: 0 - 24cm, 2 cm bin size (12 bins)
    • Y: 0 - 3.81 cm, 0.762 cm bin size (5 bins)
    • Z: 0 - 150 cm, 2.5 cm bin size (60 bins)