Difference between revisions of "New HVB"

From GlueXWiki
Jump to: navigation, search
 
(9 intermediate revisions by the same user not shown)
Line 13: Line 13:
 
<br>Cosmics with premixed 50/50 Ar/CO<sub>2</sub>, New preamp and new HVB, ADC half-range<br>
 
<br>Cosmics with premixed 50/50 Ar/CO<sub>2</sub>, New preamp and new HVB, ADC half-range<br>
  
Left: 2000V; Right: 2050V
+
NB expanded x-axis, zoomed to 1000ch from 4096. 
- NB expanded x-axis<br>
+
Left: 2000V; Right: 2050V; Far Right: 1950V (too low for software threshold of ped_mean+5sigma)<br>
  
 
{| border="0" cellpadding="2"
 
{| border="0" cellpadding="2"
Line 21: Line 21:
 
|width="400pt"|
 
|width="400pt"|
 
[[Image:newHVB_cosmics_amp_2050V.jpg|thumb|400px|New preamp and HVB - max amplitude histo for cosmics at 2050V ]]
 
[[Image:newHVB_cosmics_amp_2050V.jpg|thumb|400px|New preamp and HVB - max amplitude histo for cosmics at 2050V ]]
 +
|width="400pt"|
 +
[[Image:newHVB_cosmics_amp_1950V.jpg|thumb|400px|New preamp and HVB - max amplitude histo for cosmics at 1950V ]]
 +
 
|}
 
|}
  
  
 +
<br>Fe55 with premixed 50/50 Ar/CO<sub>2</sub>, New preamp and new HVB, ADC half-range, for a range of HV<br>
 +
Left: max amplitude histogram; Right: energy<br>
 +
Mean pedestal is around 455ch, this has been subtracted from the amplitude histogram so at 2200V it is the fADC saturating rather than the preamp. 
 +
{| border="0" cellpadding="2"
 +
|width="400pt"|
 +
[[Image:newHVB_Fe55_amp.jpg|thumb|400px|New preamp and HVB - max amplitude histo for 55Fe ]]
 +
|width="400pt"|
 +
[[Image:newHVB_Fe55_e.jpg|thumb|400px|New preamp and HVB - energy histo for 55Fe ]]
 +
|}
 +
Re-analysed with shorter integration time (100ns, prev 160ns), improved pedestal subtraction, and new 2200V run with lower pedestal
 +
{| border="0" cellpadding="2"
 +
|width="400pt"|
 +
[[Image:newHVB_Fe55_amp_2.png|thumb|400px|New preamp and HVB - max amplitude histo for 55Fe ]]
 +
|width="400pt"|
 +
[[Image:newHVB_Fe55_e_2.png|thumb|400px|New preamp and HVB - energy histo for 55Fe ]]
 +
|}
  
 +
The beginnings of a new HV efficiency plot
 +
{| border="0" cellpadding="2"
 +
|width="400pt"|
 +
[[Image:newHVB_eff_HV.gif|thumb|400px|New preamp and HVB - tracked/triggers with HV for software threshold=5]]
 +
|}
  
 
Scope traces for premixed 50/50 Ar/CO<sub>2</sub>
 
Scope traces for premixed 50/50 Ar/CO<sub>2</sub>
 +
{| border="0" cellpadding="2"
 +
|width="400pt"|
 +
[[Image:newHVB_Fe55_2100V_30s.jpg|thumb|400px|Fe55 at 2100V (50mV/div 100ns/div)]]
 +
|width="400pt"|
 +
[[Image:newHVB_cosmics_2100V_30s.jpg|thumb|400px|Cosmics at 2100V (50mV/div 100ns/div)]]
 +
|}
 +
older pics below (trigger was too high)
 
{| border="0" cellpadding="2"
 
{| border="0" cellpadding="2"
 
|width="400pt"|
 
|width="400pt"|

Latest revision as of 22:17, 8 October 2010

Max amplitude histograms for cosmics at 2100V with 50/50 Ar/CO2
Left: new preamp and new HVB, ADC half-range; right: old preamp and HVB, ADC full-range
Purple: untracked, blue: tracked (less of this with old preamp because of 2 dead central channels)

New preamp and HVB - max amplitude histo for cosmics at 2100V
Old preamp and HVB - max amplitude histo for cosmics at 2100V


Cosmics with premixed 50/50 Ar/CO2, New preamp and new HVB, ADC half-range

NB expanded x-axis, zoomed to 1000ch from 4096. Left: 2000V; Right: 2050V; Far Right: 1950V (too low for software threshold of ped_mean+5sigma)

New preamp and HVB - max amplitude histo for cosmics at 2000V
New preamp and HVB - max amplitude histo for cosmics at 2050V
New preamp and HVB - max amplitude histo for cosmics at 1950V



Fe55 with premixed 50/50 Ar/CO2, New preamp and new HVB, ADC half-range, for a range of HV
Left: max amplitude histogram; Right: energy
Mean pedestal is around 455ch, this has been subtracted from the amplitude histogram so at 2200V it is the fADC saturating rather than the preamp.

New preamp and HVB - max amplitude histo for 55Fe
New preamp and HVB - energy histo for 55Fe

Re-analysed with shorter integration time (100ns, prev 160ns), improved pedestal subtraction, and new 2200V run with lower pedestal

New preamp and HVB - max amplitude histo for 55Fe
New preamp and HVB - energy histo for 55Fe

The beginnings of a new HV efficiency plot

New preamp and HVB - tracked/triggers with HV for software threshold=5

Scope traces for premixed 50/50 Ar/CO2

Fe55 at 2100V (50mV/div 100ns/div)
Cosmics at 2100V (50mV/div 100ns/div)

older pics below (trigger was too high)

Fe55 at 2100V (50mV/div 100ns/div)